NPA
Low Pressure
The NPA product series is provided in a
miniature size as a cost effective solution
for applications that require calibrated
performance. Packaged in a SOIC14 pin
surface mount, the NPA-Low Pressure Series
is available in Gauge or Differential pressure
ranges with either amplied analog or digital
outputs. The sensor is intended for printed
circuit board mounting and delivered in tape
and reel form to simplify manufacturing
handling.
Features
Surface Mountable
Differential, Gauge, Low Pressure
2” and 5” H
2
O Full Scale
Output Options: Amplied Analog,
Digital Serial (14bit), Digital I
2
C
On chip temperature sensor in digital mode
Operating temperature range of -40 to 125°C
Total Error Band:
+/-1.5% Span at 5”H
2
O full scale
+/-2.5% Span at 2”H
2
O full scale
Surface-Mount
Pressure Sensor
Series
Amphenol
Advanced Sensors
2
Low Pressure NPA Specications
Parameter Value Units Notes
Pressure Range
2 or 5 In H
2
O 498 or 1245 Pa
Maximum Overpressure 5X Rated Pressure 400 in H
2
O Package Overpressure
Electrical @ 25°C (77°F) unless otherwise stated
Input Excitation 3.3 to 5.0 VDC 3.1 to 5.25 VDC
Environmental
Temperature Range
Operating
Compensated
Storage
-40 to +125
0 to +60
-40 to +125
°C
°C
°C
-40 to +257°F
+32 to +140°F
-40 to +257°F
Mechanical/Package
Weight ~1 grams
Media Compatibility
Positive differential and gage ports Media compatible with thermoset plastic, silicon, epoxy, RTV,
Pyrex, and UV silicone gel
Negative differential ports Dry gasses only
Performance Parameters Units Minimum Maximum Notes
Accuracy (Total Error Band) % Span
-1.5 1.5 5”H
2
O Full Scale
-2.5 2.5 2”H
2
O Full Scale
Response Time ms 2 0.5 ms Typical
Current Consumption mA 1.2 Typical