Wilcoxon Sensing Technologies
8435 Progress Drive
Frederick, MD 21701
USA
An Amphenol Company
Note: Due to continuous process improvement, specications are subject to change without notice. This document is cleared for public release.
buy.wilcoxon.com
www.wilcoxon.com
Tel: +1 (301) 330-8811
Fax: +1 (301) 330-8873
info@wilcoxon.com
SPECIFICATIONS
iT150 series
4-20 mA vibration transmitter modules
Notes:
1
Compatible with Wilcoxon models
786T and 787T (measurement range: 0° to
120°C, input signal: 0 - 1.2 VDC).
2
True peak frequency response: 10 Hz to
25 kHz.
Key features
Temperature measurement
Slim 22.5 mm case
Front panel BNC for dynamic
signal output
Manufactured in ISO 9001 facility
INPUT
Sensor types
IEPE accelerometers, IEPE
piezovelocity transducers,
IEPE dual output (vibration and
temperature) sensors
Sensor senstivities accepted:
Accelerometer
Piezovelocity
Dual output
1
10, 100, 500 mV/g
10, 100, 500 mV/ips
10 mV/°C
Frequency response:
Acceleration
2
Velocity
0.2 Hz - 20 kHz (-3 dB, -0.1 dB)
0.2 Hz - 5 kHz
Sensor powering:
Open circuit voltage
Constant-current
24 VDC, ± 5%
4.5 mA, ± 20%
Maximum dynamic signal input,
for linear response
20 Volts peak-to-peak
OUTPUT, 4-20 mA loop current
Full scale, ± 2% see Ordering information on page 2
Output type
true RMS, equivalent peak,
equivalent peak-peak, true peak
Maximum 4-20 mA loop load resistance 500 Ω
Accuracy ± 0.2% of full scale
Turn on time < 30 seconds
OUTPUT, buffered dynamic
Gain, RTI sensor 1.0 ± 2%
Noise RTO, broadband, 1 Hz - 10 kHz, RMS ≤0.0001 Volts
Output type DC-coupled
ENVIRONMENTAL
Power:
Voltage (Vin)
Current draw
11 - 32 VDC
125 mA at 24 VDC (3 watts max)
Temperature, operating, ambient –40° to +70°C
PHYSICAL
Mounting snap into 35 mm DIN rail
Dimensions:
Width
Depth (front of BNC to back of DIN rail)
Height
22.5 mm (0.86”)
127 mm (4.98”)
100 mm (3.90”)
99304 Rev.A.4 11/19
1
For dimensions and ordering
information, see page 2.
For system architecture, see
page 3.
Wilcoxon Sensing Technologies
8435 Progress Drive
Frederick, MD 21701
USA
An Amphenol Company
Note: Due to continuous process improvement, specications are subject to change without notice. This document is cleared for public release.
buy.wilcoxon.com
www.wilcoxon.com
Tel: +1 (301) 330-8811
Fax: +1 (301) 330-8873
info@wilcoxon.com
2
Ordering information
Dimensions
99304 Rev.A.4 11/19
Notes:
* True peak detection option available for
Input/Output type “A” only.
** Displacement output option available for
Input type “V” only.
Sensitivity
10
mV/g,
mV/ips
100
500
Detector type
RMS True RMS
P Peak (equiv.)
PP Peak-to-peak (equiv.)
TP * True peak (10-25,000 Hz)
Input type
A Acceleration
V Velocity
Output type Units Full scale
A
g 1, 5, 10, 20, 30, 50
m/s
2
50, 100, 200, 300, 500
V
ips 0.5, 1, 2, 3, 5
mm/s 15, 20, 25, 30, 45, 50, 100
D**
mils 10, 20, 25, 100
mm 0.2, 0.5, 1, 2, 3, 4, 5
Output type
A Acceleration
V Velocity
D** Displacement
iT150
Detector type Output type F
MIN
(Hz) – F
MAX
(Hz)
RMS
Peak
Peak-to-peak
A, V, D**
0.2 200
0.5 500
A, V
1 1,000
10 1,000
2 2,000
5 5,000
A
10 10,000
20 20,000
True peak* A 10 25,000
F
MIN
xed with F
MAX
(select desired
frequency range)
ISO 10816-3
Output type Units
A
g
m/s/s (m/s
2
)
V
ips
mm/s
D**
mils**
mm
Selectable parameters are in bold.
0.891
3.90
4.473
4.883