AZEV116/132
16A /32A
POWER RELAY
FEATURES:
• 16 Amp switching (AZEV116)
• 32 Amp switching (AZEV132)
• Monitor contacts available
• 1500 Amp short circuit current (carrying)
• Wide contact gap > 2.25 mm
• Dielectric strength 4000 Vrms
• UL: E365652
• CQC: 19002216104
• TUV: B0887930014
CONTACTS:
COIL
NOTES
GENERAL DATA
1.All values at 20℃(68℉)
2.Relay may pull in with less than “Must Operate” value
3.Specifications subject to change without notice
ZETTLER RELAY (XIAMEN) CO., LTD.
www.zettlercn.com
No.6 Xinjing Road, Xinyang Industrial Zone, Haicang District, Xiamen, China 361028
Arrangement DPST (1 Form A and 1 Form B)
Ratings
Resistive load:
AZEV116
Max. switched power: 480 W or 6400 VA
Max. switched current: 16 A
Max. switched voltage: 30 VDC or 400 VAC
AZEV132
Max. switched power: 960 W or 12800 VA
Max. switched current: 32 A
Max. switched voltage: 30 VDC or 400 VAC
Rated Load AZEV116
TUV/CQC
16 A at 400 VAC, Res. 50 k, @85℃ (NO.)
20 A at 400 VAC, Res. 30 k, @85℃ (NO.)
10 mA at 12 VDC, Res. 50 k, @85℃ (NC.)
AZEV132
32 A at 400 VAC, Res. 50 k, @85℃ (NO.)
40 A at 277 VAC, Res. 6 k, @45℃ (NO.)
10 mA at 12 VDC, Res. 50 k, @85℃ (NC.)
UL/CUL AZEV116
16 A at 277 VAC, Res. 50 k, @85℃ (NO.)
20 A at 277 VAC, Res. 30 k, @85℃ (NO.)
10 mA at 12 VDC, Res. 50 k, @85℃ (NC.)
AZEV132
32 A at 277 VAC, Res. 50 k, @85℃ (NO.)
40 A at 277 VAC, Res. 6 k, @45℃ (NO.)
10 mA at 12 VDC, Res. 50 k, @85℃ (NC.)
Material Silver tin oxide (N.O.), gold plating(N.C.)
Resistance
<100 mΩ initially
(at 6V,1A, voltage drop method)
Power
At pickup Voltage
Max. Continuous
Dissipation
Temperature Rise
875 mw (typical)
2.23 W at 20℃(68℉) ambient
70℃ Max. at Rated voltage,85℃
Temperature
Max. 155℃(311℉)classF
Life Expectancy
Mechanical
Electrical
Minimum operations
100,000 cycles Min.
See rated load
Operate Time 30 ms Max. at nominal coil voltage
Release Time
10 ms Max. at nominal coil voltage
(with no coil suppression)
Dielectric Strength
(Initial)
4.0 kVrms(coil and power contacts)
2.5 kVrms(between open power contacts)
4.0 kVrms(monitor and power contacts)
Pulse Current
Capability (Carrying)
AZEV116 ≥ 1.02kA Ip 2.5kA²s I²t
AZEV132 ≥ 1.50kA Ip 6.0kA²s I²t
Insulation Resistance
1,000MΩ min. at 20℃ 500VDC 50% RH
Holding voltage
Greater than 35% of nominal coil voltage
Dropout
Greater than 5% of nominal coil voltage
Ambient Temperature
Operating
Storage
At rated coil voltage
-40 ℃(-40 ℉ )to85℃(185 ℉)
-40 ℃(-40 ℉ ) to 105 ℃(221 ℉)
Vibration
1.5mm DA at 10-55 Hz
Enclosure
P.B.T, Polyester
Terminals
Tinned copper alloy, P.C.
Max. Solder Temp.
270 ℃ (518 ℉)
Max. solder time
5 seconds
Weight
35g
05/12/19