Property Test Method Value
Uncured product
Appearance Thixotropic Paste
Colour A Part Pale grey
Colour B Part Black
Cure Type Addition
Max Cure Hrs @ 25 °C 5 hrs
Max Cure Mins @ 100 °C 2 mins
Mix Ratio 1:1
Pot Life mins 60 mins
Rheology Paste
Self Bonding No
Viscosity A-Part mPas Brookfield 248000 mPas
Viscosity B-Part mPas Brookfield 390000 mPas
Viscosity Mixed mPas Brookfield 320000 mPas
Cured product
After 7 days cure at 23°+/-2°C and 50+/-5% humidity
CTE Linear ppm/°C 186 ppmC
CTE Volumetric ppm/°C 558 ppmC
Colour Black
Duro Shore 00 ASTM D 2240-95 50
Linear Shrinkage % 0.1 %
Max Working Temp +°C AFS_1540B 200 °C
Min Working Temp - °C -60 °C
SG BS ISO 2781 2.3
Thermal Conductivity W/mK 1.7 W/mK
UL 94V-0 Yes
Storage
Max storage temperature
°C
25 °C
Shelf life 6 mths
Electrical properties
Dielectric Constant @ 1kHz ASTM D-150 4.9
Dissipation Factor @ 1kHz ASTM D-150 0.006
Volume Resistivity ohms cm ASTM D-257 9.26E+12 ohms cm
SE2010
SILCOTHERM 2 Part silicone gap filler
Introduction
This is a two part, thermally conductive, thixotropic material,
which cures at room temperature or can be accelerated with heat.
It is specifically formulated to give low hardness and resistance to
slump and features low and high temperature mechanical and
chemical stability. It remains flexible and has a natural low level
tack, ideal for applications where a strong mechanical or chemical
bond is not required. It has a controlled volatile content and an
easy mix ratio by volume or weight.
Key Features
Thermally conductive
UL94 V0 Approved
Controlled volatile content
Non slumping
Use and Cure Information
IMPORTANT:
The ‘A’ part of product
contains the platinum catalyst; great care should be taken when
using automatic dispensing equipment. Please ensure that it is not
contaminated by residual hydride containing rubber in the
dispensing equipment, as curing will result. If in doubt, it’s advised
to thoroughly purge the equipment with a suitable hydrocarbon
solvent or silicone fluid.
Mixing
This gap filler can be supplied in bulk containers for use with
automatic mixing equipment or in a twin cartridge system and
static mixer to provide for easy application and mixing.
Inhibition of Cure
Great care must be taken when handling and mixing all addition
cured silicone elastomer systems, ensuring that all the mixing
tools (vessels and spatulas) are clean and constructed in
materials which do not interfere with the curing mechanism. The
cure of the rubber can be inhibited by the presence of compounds
of nitrogen, sulphur, phosphorus and arsenic; organotin catalysts
and PVC stabilizers; epoxy resin catalysts and even contact with
materials containing certain of these substances e.g. moulding
clays, sulphur vulcanised rubbers, condensation cure silicone
rubbers, onion and garlic.
Curing Conditions
The data offers a guide to the rate of cure at various
temperatures, mixing of the components at temperatures between
15 and 25°C is recommended to ensure adequate pot life for
degassing and handling. The pot life can be extended to several
hours by chilling the components before mixing.
Health and Safety
Safety Data Sheets available on request.
Packaging
CHT Gap Fillers are available in a variety packaging including bulk containers. Please contact our sales department for more information.
Revision Date : 02/11/2017
Download Date : 10/08/2019
Technical Data Sheet
The information and recommendations in this publication are to the best of our knowledge reliable. However, nothing herein is to be construed as warranty or
representation. Users should make their own test to determine the applicability of such information or the suitability of any products for their own particular
purposes. Statements concerning the user of the products described herein are not to be construed as recommending the infringement of any patent and no liability
for infringement arising out of any such use is to be assumed. All values are typical and should not be accepted as a specification
CHT UK Bridgwater LTD, Registered Office: Showground Road. Bridgwater. Somerset.
TA6 6AJ. UK Registered No 01185365
Tel: +44 (0)1278 411400, Email: info@acc-silicones.com, Web: www.acc-silicones.com