MAJOR RATINGS AND CHARACTERISTICS (T = 25°C unless otherwise noted)
A
PARAMETER
V
V
SYMBOL
MTP100
UNIT
1900
08
900 1100 1300
1800800 1000 1200 1600
18
12
10 16
1700
1800800 1000 1200 1600
V
Maximum repetitive peak reverse voltage
Peak reverse non-repetitive voltage
Maximum DC blocking voltage
Maximum average forward rectified output current
Peak forward surge current single sine-wave superimposed on
rated load
Rating (non-repetitive, for t greater than 1 ms and less than 10 ms)
for fusing
RMS isolation voltage from case to leads
Operating junction storage temperature range
V
RRM
V
RSM
I
FSM
V
DC
I
F(AV)
V
ISO
2
I t
2500
7200
100
-40 to 150
1200
2
A s
A
A
V
ºC
ELECTRICAL CHARACTERISTICS (T = 25°C unless otherwise noted)
A
PARAMETER
V
µA
SYMBOL
MTP100
UNIT
08 18
12
10 16
Maximum instantaneous forward drop per diode
Maximum reverse DC current at rated DC blocking
V
F
I
R
5000
1.3
20
voltage per diod
TEST
CONDITIONS
I = 100A
F
T = 25°C
A
T = 150°C
A
THERMAL AND MECHANICAC (T = 25°C unless otherwise noted)
A
PARAMETER
°C/W
SYMBOL
MTP100
UNIT
08 18
12
10 16
Typical thermal resistance
(1) With heatsink, single side heat dissipation, half sine wave.
(1)
R
θJC
0.20
(2) M6 screw.
Notes
Storage temperature range
T
STG
-40 to 125
ºC
T
J
TEST CONDITIONS
junction to case
Single-side heat dissipation, sine
half wave
Mounting
± 10 %
to heatsink M6
A mounting compound is recommended
and the torque should be rechecked after
a period of 3 hours to allow for the spread
of the compound.
4
Nm
to terminals M5
4
Approximate weight
195
torque
g
- Module type: ”MTP” for 3Ø Brıdge
1
2
3
-
RRM
Device code
- Voltage code: code x 100 = V
I rating: "100" for 100A
F(AV)
2
MTP
100
16
3
1
RoHS
RoHS
Nell High Power Products
MTP100
Page 2 of 3
www.nellsemi.com