SMART HART NaK FILLED MELT PRESSURE TRANSMITTERS
HKE SERIES - CURRENT OUTPUT
AND PERFORMANCE LEVEL ‘c’ 4...20mA Output
The HKE series of Gefran are pressure transmitters with
HART communication protocol for using in high tempera-
ture environment.
The main characteristic of this series is the capability to
read temperature of the media up to 538°C.
The constructive principle is based on the hydraulic tra-
smission of the pressure.
The fluid-filled system assures the temperature stability.
The physical measure is transformed in a electrical mea-
sure by means of strain-gauge technology.
TECHNICAL SPECIFICATIONS
MAIN FEATURES
• Pressure ranges from: 0-35 to 0-1000 bar / 0-500 to
0-15000 psi
• Accuracy: < ±0.25% FSO (H); < ±0.5% FSO (M)
• Hydraulic transmission system for pressure signal
guarantees stability at working temperature (NaK).
• Liquid conforming to RoHS Directive. NaK is defined as a
safe substance (GRAS)
• Quantity of NaK contained per model: HKE0 series
(30mm³) [0.00183 in³], HKE1, HKE2, HKE3 (40mm³)
[0.00244 in³]
• 1/2-20UNF, M18x1.5 standard threads; other types
available on request
• Autozero function on board / external option
• Inconel 718 diaphragm with GTP+ coating for temperatures
up to 538°C (1000°F)
• 15-5 PH diaphragm with GTP+ coating for temperatures up
to 400°C (750°F)
• Hastelloy C276 diaphragm for temperatures up to 300°C
(570°F)
• 17-7 PH corrugated diaphragm with GTP+ coating for
ranges below 100bar-1500psi (up to 400°C/750°F)
• Stem material: 17-4 PH
GTP+ (advanced protection)
Coating with high resistance against corrosion, abrasion
and high temperature
AUTOZERO FUNCTION
All signal variations in absence of pressure can be elimina-
ted by using the Autozero function.
This function is activated by closing a magnetic contact loca-
ted on the transmitter housing.
The procedure is permitted only with pressure at zero.
This function can be activited via HART as well.
Accuracy (1)
H <±0.25%FSO (100...1000 bar)
M <±0.5%FSO (17...1000 bar)
Resolution 16 bit
Measurement range
0..17 to 0..1000bar
0..250 to 0..15000psi
Rangeability 3:1
Maximum overpressure (without
degrading performances)
2 x FS
1.5 x FS above 700bar/10000psi
Measurement principle Extensimetric
Power supply 13...30Vdc
Maximum current absorption
23mA
(40mA with relay optional)
Output signal Full Scale (FSO) 20mA
Zero balance (tollerance ± 0.25%
FSO)
4mA
Calibration signal 80% FSO
Power supply polarity reverse
protection
YES
Compensated temperature range
housing
0...+85°C
Operating temperature range
housing
-30...+85°C
Storage temperature range housing -40...+125°C
Thermal drift in compensated range:
Zero / Calibration / Sensibility
< 0.02% FSO/°C
Diaphragm maximum temperature 538°C / 1000°F
Zero drift due to change in process
temperature (zero)
< 3.5 bar/100°C / < 28 psi/100°F
Thermocouple (model HKE2) STD: type “J” (isolated junction)
Protection degree
(with 6-pole female connector)
IP65
FSO = Full scale output :
(1) BFSL method (Best Fit Straight Line): includes combined effects of Non-Linearity,
Hysteresis and Repeatability
MECHANICAL DIMENSIONS
NOTE: dimensions refer to rigid stem length option “4” (153 mm– 6”)
WARNING: For installation use a maximum tightening torque of 56 Nm (500 in-lb)
HKE1
HKE0
1/2 - 20UNF
D1
D2
D3
D4
D5
A
B
C
Ch
[Hex]
ø7.8 -0.05
[ ø0.31” -0.002 ]
ø10.5 -0.025
[ ø0.41” -0.001 ]
ø10.67
[ ø0.42” ]
ø12.7
[ ø0.5” ]
5.56 -0.26
[ 0.22” -0.01 ]
11.2
[ 0.44” ]
15.74
[ 0.62” ]
16
[ 5/8” ]
ø10 -0.05
[ ø0.394” -0.002 ]
M18x1.5
D1
D2
D3
D4
D5
A
B
C
Ch
[Hex]
ø16 -0.08
[ ø0.63” -0.003 ]
ø18
[ ø0.71” ]
6 -0.26
[ 0.24” -0.01 ]
14.8 -0.4
[ 0.58” -0.016 ]
19
[ 0.75” ]
19
[ 3/4” ]
ø16 -0.4
[ ø0.63” -0.016 ]