Data sheet
Discharge Current Maximum
Discharge Temp Nominal
20 Degrees C
Discharge Temp Maximum
Discharge Temp minimum
Discharge Cut off V Nom
11.2 Volts
Discharge Cut off V Max
12 Volts
Discharge Cut off V Min
10.8 Volts
Protection Circuit
4S-12 Amp
Fuse Rating
Controlled by PCM
Thermal Fuse Rating
91 Deg C
Reverse Charge Limit
3 Amp
Storage Temperature Nom
20 Deg C (12 Months)
Storage Temperature Max
30 Deg C
Storage Temperature Min
Minus 20 C
Battery Dimensions
Length
135mm
Width
80mm
Height
45mm
Packing And Weight
Packaging
Industrial
Battery Weight
0.875Kg
EXTERNAL APPEARANCE
The battery Pack Is Housed In A Black Plastic Plastic Case With Output Lead and AXR Connector
WARRANTY
One (1) year limited warranty against workmanship and material defects.
UN T1-T8 Tested ( Class 9 UN3480 Transportation applies)
CAUTION
1. Observe Correct Polarity
2. Do Not Store In A Fully Discharged Condition
3. Do not charge /discharge with more than the specified current.
4. Do Not Short Circuit
5. Do not incinerate or mutilate the cell/battery.
6. Do not solder directly to the cell /battery.
9. Keep away from children. If swallowed, contact a physician at once.
Minus 10 Degrees C
60
12.0 Amps
05/12/2007 MGL2802 Page 2