3. Composi t ion/ informati on on ingredie nts
Solid article. This article is a double-sided adhesive tape on an expan ded alumi n um mesh carrier. It consi sts of an adhesive la yer
on each si de and a release liner covering each adhesive la yer.
Common name and s ynonyms
The exac t concentrations of the above list ed chemic als are being wi thheld as a trade secret.
None req uired under normal condit ions. However, i f the art icle is damaged and/or
improperly used:
If i nhaled, move to fresh ai r. If breathing is di fficult, give oxygen by quali fied medical
personnel only. If breat hing has stopped, give ar tifi cial res pirati on. Get medical attent ion if
irritation devel ops and p ersists.
None req uired under normal condit ions. H ow ever, if the artic le is damaged and/or
improperly used:
For skin contact, wash with soap and water whil e removing contaminated clothing. Get
medic al attention if i rritation develops and persists.
None req uired under normal condit ions. H ow ever, if the artic le is damaged and/or
improperly used:
Rinse thoroughly with pl enty of water, also under the eyeli ds. Remove contact lens es if
present and easy to do. Get medical at tention i f irritation devel
ops and persists.
Not considered to be a hazard.
If i ngested, do not induce vomiting. R inse mouth. Never give anythi ng by mouth t o an
unconscious person. Obtain medical att ention if symptoms develop and persist.
Most important symptoms and
effects, both acute and delayed
This product is consi dered an 'articl e' under 29 CFR Part 1910.1200. Under normal
conditions of use, users of the produc t cannot be exposed to i ts harmful content s.
Fumes f rom heated product m ay irrit ate respi ratory tr act. Inhal ation of f um es may res ult in
metal fume fever, a flu
-like illness . Symptoms of metal fume fever m ay include f ever, fatigue,
vomiting, muscle aches and shortness of breath.
ted, may cause irritation to mucous membranes. May cause naus ea,
Indication of any immediat e
medical attention and speci al
treatment needed
Provide general support ive meas ures and treat symptomatically.
Ensure that medical personnel are aware of t he m aterial (s) invol ved, and take precautions t o
protect themselves. S how this safety data sheet to the doct or in att endance.
5. Fire-fighting m e asur e s
Suitable ext inguishing media
Use medi a suitable to the s urrounding f ire such as water fog or fine spray, alcohol foams,
carbon dioxide and dry chemical.
Unsuitable extinguishing
media
Toxic fumes may be released d uring a fi re. The pressure in sealed cont ainers can increase
under the influence of heat.
Specific hazards arising from
the chemi cal
Special prot ective equipment and
precautions for fire
-fighters
Firefighters must us e standard protect ive equipme nt incl uding flame retardant coat, hel m et
with face shield, glo
ves, rubber boots, and in enclosed spaces, SCBA. Firefight ers should
wear proper protective eq uipment and self
-cont ained breathi ng apparatus with full face
piece operated i n positive pressur e mode.
Fire-fighting
equipment/instructions
Move cont ainers from fi re area if s afe to do so. Cool clos ed containers exposed to f ire with
water spray. Do not allow run
-off from fire fighting to enter drains or water cour ses. Dike for
SDS No. PHC-201 Version #: 1 Issue date: 05-15-2015