ICS Zone 2/22 Wea therproof P age/P arty
®
Station Quick Installation Guide
Important Safety Instructions
This equipment is suitable for use in Zone 2/22 hazardous areas OR non-hazardous locations only. Combinations of equipment in your syst em are subject t o
investigation by the local Authori ty Havin g Jurisdic tion at th e time of installat ion.
Read, follow, and retain instructions – All safety and operating instructions should be read and followed before operating the unit. Retain instructions for future
reference.
Heed warnings – Ad here to all warnings on the unit and in the operating instructions.
Attachments – Attachments not recommended by the product manufacturer should not be used, as they may cause hazards. Maximum system cable length is no t to
exceed two miles.
Servicing – Do n ot attempt to service t his unit by yourself. Opening or removing covers may expose you t o dangerous voltage or other hazards. Refer all servici ng to
qualified service personnel.
WARNING – POTENTIAL ELECTROSTATIC CHARGING HAZARD – Model 10401-201 Headset and 10416-103 Extension Cord should be used in Group IIB or
Grou p II A areas only.
Capacita nce valu es of 140 pF to 580 pF were measured on the ext er nal metallic unearthed co mponents of this equipment. As such, special care must be taken in
installation location an d environment to address this hazard. See EN TR50404, “Electros tat ics – Code of practice for avoidance of hazards du e to static elect ricity” for
additional information in regards to proper installation and potential hazards.
WARNING – EXPLOSION HAZARD – Do not disconnect equipment unless power has been removed or the area is known to be non-hazardous.
Avertissement – Risque d’explosion – Avant de débrancher l'équipement, couper le courant ou assurer que le secteur est su pour n'être pas hasardeux.
WARNING
In 24 V dc systems: Under NO condition should this equipment be operated from a battery charger without the batteries connected.
In 24 V dc systems, most chargers have an un loaded out put of 35 to 45 volts that can quickly damage the equipment designed for n o mi nal 24 volt s. The maxim um
battery volta g e should never exc eed th e maximu m speci fi ed input voltage.
General Information and Available Options
This guide covers the installation of the ICS Zone 2/22 Weatherproof Page/Party
®
Station. Figure 1 shows configurations with the following options:
Universal ac or 24 V dc power Auxiliary jack
VLC
RTU Emergency party line (EPL)
Single party system Alternate page
SmartSeries
Amplifier only
All Zone 2/22 ICS Stations are wired in parallel. Good system layout design minimizes the cable required. Refer to Pub. 42004-734L2 at th e
“Manu als & Specs” link at www.gai-tronics.com
for detailed explanations of the available configuration options and adjustments, system design
information, and warranty.
Mounting and Wiring
Mount the enclosure using the four 0.31-inch (8 mm) diameter holes located on the mounting flanges with 5/16-inch (M6) hardware.
Remove front panel and drill or punch wire entry openings in the rear enclosure, or gland plate when present. See Figure 2 for suggested locations.
There must be a minimum of ½ inch (12.7 mm) of material between wire en t r y ho les. The recomme nded entry is via t he enclosure bottom to prevent
moisture from dripping onto the terminals. Top entry is not recommended. Basic wiring connections are shown on Figure 3. Use GAI-Tronics
60029 Series multi-party cable or 60038 Series single party cable terminated with #6 spade lugs. Torque the terminal block screws to 8–10 in-lbs.
(0.90–1.13 n-m) when attaching th e spade lugs.
Ensure any unused openings are sealed with proper fittings per local standards. All metric cable entry devices and blanking elements shall be
certified for Zone 2/22 applications with an IP66 rating, suitable for conditions of use and correctly installed. Use field wiring suitable for the
ambient temperature.
Figure 1. ICS Zone 2/22 Weatherproof Station (AC Version) with available options
Pub. 42004-734L2DQG
ICS Zone 2/22 Weatherproof Page/Party
®
Station Quick Installation Guide Page 2 of 2
f:\standard i oms - cur rent release\ 42004-xxx xqg quick guides\ 42004-734l 2dqg.doc
11/14
Available Adjustments
Most optional equipment is preconfigured to a default standard at the factory. The following is a
partial list of the available adjustments and settings that may be needed:
Main PCBA VLC Option SmartSeries Option
Speaker Volume Speaker Volume FSK Trans mi t Level
Receiver Volume VLC Override Address
Transmit Level Te st To n e
Mutual Muting Page C ontrol
Termination PCBA
Remote Signaling Speaker I mpedance
Figure 3. Typical installation wiring configuration
N
OTE: Station input power can be through system cable or through a separate power source cable.
See Pub. 42004-734L2 for the possible beacon, RTU activation, dc option, and speaker impedance
configurations.
Front Cover Reattachment
Connect any cable harnesses that were disconnected during mounting. Place the front cover inside the rear enclosure, bein g careful not to pinch any
cables. Attach the front cover with the four screws and washers provided. Torque the screws to 50 in-lbs (5.65 n-m).
CE Mark Certificate No.
Notified Body ID No. 0539
UL International DEMKO A/S
Lyskear 8
DL-2730 Herlev
Denmark
DEMKO 10 ATEX 1010664x .............................................. II 3 G Ex ic nA IIC T4 Gc and II 3 D Ex ic tb IIIC T135ºC Dc
IECEx UL 10.0038x ............................................................. Ex ic nA IIC T4 Gc and Ex ic tb IIIC T135ºC Dc
Figu r e 2. Suggested wire
entry locations