Technical Data Sheet
RPC-1.00
Adaptor
Plug/Jack
01S101-K20D3
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260 D-84526 Tittmoning Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Email : info@rosenberger.de
Page
1 / 2
Dieses Dokument ist urheberrechtlich geschützt
This document is protected by copyright Rosenberger Hochfrequenztechnik GmbH & Co. KG
RF_35/09.14/6.2
All dimensions are in mm; tolerances according to ISO 2768 m-H
Interface
According to IEC 61169-31
Documents
N/A
Material and plating
Connector parts Material Plating
Center conductor CuBe Gold, min. 1.27 µm, over nickel
Outer conductor CuBe or equiv. Gold, min. 1.27 µm, over nickel
Coupling nut Stainless steel Passivated
Dielectric PEEK
Technical Data Sheet
RPC-1.00
Adaptor
Plug/Jack
01S101-K20D3
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260 D-84526 Tittmoning Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Email : info@rosenberger.de
Page
2 / 2
Dieses Dokument ist urheberrechtlich geschützt
This document is protected by copyright Rosenberger Hochfrequenztechnik GmbH & Co. KG
RF_35/09.14/6.2
Electrical data
Frequency DC to 110 GHz
Return loss 20 dB, DC to 20 GHz
17 dB, 20 GHz to 50 GHz
15 dB, 50 GHz to 75 GHz
12 dB, 75 GHz to 110 GHz
Mechanical data
Mating cycles 500
Maximum torque 0.70 Nm
Recommended torque 0.35 Nm
Gauge 0.00 mm to 0.03 mm
General standard definitions
For proper operation the vector network analyzer (VNA) needs a model describing the electrical behaviour
of this standard. The different models, units, and terms used will depend on the VNA type and they will have to
be entered into the VNA. All values are based on typical geometry and plating.
Offset Z
o
/ Impedance / Z
o
50
Offset Delay 39.094 ps
Length (electrical) / Offset Length 11.72 mm
Offset Loss 7.90 G/s
Loss 0.0268 dB/
GHz
Environmental data
Operating temperature range
1
+20 °C to +26 °C
Rated temperature range of use
2
0 °C to +50 °C
Storage temperature range -40 °C to +85 °C
RoHS compliant
1
Temperature range over which these specification are valid.
2
This range is underneath and above the operating temperature range, within the adaptor is fully functional
and could be used without damage.
Packing
Standard 1 pce in box
Weight 2.1 g/pce
Draft Date Approved Date Rev. Engineering change number Name Date
Herbert Babinger 23.03.06 Ronny Mark 15.03.17 g00 17-0439 Marcel Panicke 15.03.17
While the information has been carefu
lly compiled to the best of our knowledge, nothing is intended as representation or warranty on
our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve
our
products, we reserve the right to make changes judged to be necessary.