EPC – EFFICIENT POWER CONVERSION CORPORATION | WWW.EPC-CO.COM | COPYRIGHT 2018 | | 1
QUALIFICATION REPORT
EPC Reliability & Quality
EPC eGaN® FET
Qualication Report
EPC2045
EFFICIENT POWER CONVERSION
Robert Strittmatter, Director of Engineering, Efficient Power Conversion Corporation
This report summarizes the Product Qualication results for EPC
part number EPC2045 which meets all required qualication
requirements and is released for production.
Qualication Test Overview
EPC’s eGaN FETs were subjected to a wide variety of stress tests under
conditions that are typical for silicon-based power MOSFETs. These tests
included:
High temperature reverse bias (HTRB): Parts are subjected to a drain
source voltage at the maximum rated temperature
– High temperature gate bias (HTGB): Parts are subjected to a gate
source voltage at the maximum rated temperature
Temperature cycling (TC): Parts are subjected to alternating high
and low temperature extremes
High temperature high humidity reverse bias (H3TRB): Parts are
subjected to humidity under high temperature with a drain-source
voltage applied
Moisture sensitivity level (MSL): Parts are subjected to moisture,
temperature, and three cycles of reow.
The stability of the devices is veried with DC electrical tests after stress
biasing. The electrical parameters are measured at time-zero and at
interim readout points at room temperature. Electrical parameters such
as the gate-source leakage, drain-source leakage, gate-source threshold
voltage, and on-state resistance are compared against the data sheet
specications. A failure is recorded when a part exceeds the datasheet
specications. eGaN FETs are stressed to meet the latest Joint Electron
Device Engineering Council (JEDEC) standards when possible.
Parts were mounted onto FR5 (high Tg FR4) or polyimide adaptor cards.
Adaptor cards of 1.6 mm in thickness with two copper layers were used.
The top copper layer was 1 oz. or 2 oz., and the bottom copper layer
was 1 oz. Kester NXG1 type 3 SAC305 solder no clean ux was used in
mounting the part onto an adaptor card.
Scope
The testing matrix in this qualication report covers the qualication
of EPC2045, EPC2051, and EPC2052 listed in the table below.
EPC2045, EPC2051, and EPC2052 have the same voltage ratings and
device processing.
Part Number
Voltage
(V)
R
DS(on)
(mΩ)
Die Size
(mm x mm)
EPC2045 100 7 L (2.5 x 1.5)
EPC2052 100 12.5 M (1.5 x 1.5)
EPC2051 100 25 S (1.3 x 0.85)
Stress Test Part Number
Voltage
(V)
Die Size
(mm x mm)
Test Condition # of Failure
Sample Size
(sample x lot)
Duration (Hrs)
HTRB EPC2045 100 L (2.5 x 1.5) T = 150
o
C, V
DS
= 80 V 0 77 x 1 1000
HTRB EPC2051 100 S (1.3 x 0.85) T = 150
o
C, V
DS
= 80 V 0 77 x 2 1000
High Temperature Reverse Bias
Parts were subjected to 80% of the rated drain-source voltage at the maximum rated temperature for a stress period of 1000 hours.
Table 1. High Temperature Reverse Bias Test
QUALIFICATION REPORT
EPC Reliability & Quality
EPC – EFFICIENT POWER CONVERSION CORPORATION | WWW.EPC-CO.COM | COPYRIGHT 2018 | | 2
Stress Test Part Number
Voltage
(V)
Die Size
(mm x mm)
Test Condition # of Failure
Sample Size
(sample x lot)
Duration (Hrs)
HTGB EPC2045 100 L (2.5 x 1.5) T = 150
o
C, V
GS
= 5.75 V 0 77 x 2 1000
HTGB EPC2051 100 S (1.3 x 0.85) T = 150
o
C, V
GS
= 5.75 V 0 77 x 2 1000
High Temperature Gate Bias
Parts were subjected to 5.75 V gate-source bias at the maximum rated temperature for a stress period of 1000 hours.
Table 2. High Temperature Gate Bias Test
Stress Test Part Number
Voltage
(V)
Die Size
(mm x mm)
Test Condition # of Failure
Sample Size
(sample x lot)
Duration (Hrs)
HTS EPC2045 100 L (2.5 x 1.5) T = 150
o
C, Air 0 77 x 2 1000
HTS EPC2051 100 S (1.3 x 0.85) T = 150
o
C, Air 0 77 x 4 1000
High Temperature Storage
Parts were subjected to heat at the maximum rated temperature.
Table 3. High Temperature Storage Test
*Note - EPC2051 is supplied in passivated die form with copper pillars.
Customers will qualify the die in their products themselves.
The 500 cycle TC data is for reference only.
Stress Test Part Number
Voltage
(V)
Die Size
(mm x mm)
Test Condition # of Failure
Sample Size
(sample x lot)
Duration (Cys)
TC EPC2045 100 L (2.5 x 1.5) -40 to +125
o
C, Air 0 77 x 3 1000
TC EPC2051 100 S (1.3 x 0.85) -40 to +125
o
C, Air 0 77 x 3 500*
Temperature Cycling
Parts were subjected to temperature cycling between -40°C and +125°C, with a ramp rate of 15°C/min and dwell time of 5 minutes in accordance
with the JEDEC Standard JESD22A104.
Table 4. Temperature Cycling Test
Stress Test Part Number
Voltage
(V)
Die Size
(mm x mm)
Test Condition # of Failure
Sample Size
(sample x lot)
Duration (Hrs)
H3TRB EPC2045 100 L (2.5 x 1.5) T = 85
o
C, RH = 85%, V
DS
= 80 V 0 77 x 1 500
H3TRB EPC2051 100 S (1.3 x 0.85) T = 85
o
C, RH = 85%, V
DS
= 80 V 0 77 x 2 1000
High Temperature High Humidity Reverse Bias
Parts were subjected to a drain-source bias at 85% RH and 85°C for a stress period of 500 or 1000 hours. The testing was done in accordance with
the JEDEC Standard JESD22A101.
Table 5. High Temperature High Humidity Reverse Bias Test
Stress Test Part Number
Voltage
(V)
Die Size
(mm x mm)
Test Condition # of Failure
Sample Size
(sample x lot)
Duration (Hrs)
MSL1 EPC2051 100 S (1.3 x 0.85) T = 85
o
C, RH = 85%, 3 reow 0 77 x 3 168
Moisture Sensitivity Level
Parts were subjected to 85% RH at 85°C for a stress period of 168 hours. The parts were also subjected to three cycles of Pb-free reow in
accordance with the IPC/JEDEC joint Standard J-STD-020.
Table 6. Moisture Sensitivity Level Test
Note - EPC2045 is qualied by matrix.