Assembly instruction
MA_99A5
Series: special
Power connector 2 pin
Date Name
Tools:
Drawn
17.11.2014
E. Truc-Vallet
Knife ……
Check.
24.04.2018
J. Peteranderl
open-ended spanner 24 - 29 ……
Appr. 24.04.2018
E. Truc-Vallet
or 2 adjustable spanners ……
Dept. COM Hex key 2.5 ……
300 18-0739 M_Wallner 24.04.2018
Hochfrequenztechnik
84526 Tittmoning
Diagonal pliers ……
200 15-v043 E. Truc-Vallet 26.01.2015 Electrical tape ……
100 14-m559 E. Truc-Vallet 17.11.2014 Wire ferrules ……
Rev. Change-no
Name Date Page 1 of 2
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF ROSENBERGER
HOCHFREQUENZTECHNIK GMBH WITHOUT THEIR CONSENT IT MAY
NOT BE REPRODUCED OR GIVEN TO THIRD PARTS.
Formblatt: TCC_FB_35 /04 2006/ 1.0
ISO – Projektion
If your cable diameter is smaller than 9mm,
add the extra gasket into the cable gland.
Slide the connector body in the correct position onto the
cable.
A: connector head B: connector body C: extra gasket
C
B
A
Prepare the cable according to the picture above: Divide
the shield in half, fold back half of it, twist half of it.
Prepare the cable according to the picture
above.
35mm
10mm
35mm
35mm
10mm
35mm
35mm
I. 2 way power with shield
II. Coax power cable
10mm
10mm
Rosenberger recommends to use wire ferrules with stranded wires. Make sure the wire ferrules have
the adequate size. If they are longer than 10mm, shorten them.
I. 2 way power with shield II. Coax power cable
Assembly instruction
MA_99A5
Series: special
Power connector 2 pin
Date Name
Tools:
Drawn
17.11.2014
E. Truc-Vallet
Knife ……
Check.
24.04.2018
J. Peteranderl
open-ended spanner 24 - 29 ……
Appr. 24.04.2018
E. Truc-Vallet
or 2 adjustable spanners ……
Dept. COM Hex key 2.5 ……
300 18-0739 M_Wallner 24.04.2018
Hochfrequenztechnik
84526 Tittmoning
Diagonal pliers ……
200 15-v043 E. Truc-Vallet 26.01.2015 Electrical tape ……
100 14-m559 E. Truc-Vallet 17.11.2014 Wire ferrules ……
Rev. Change-no
Name Date Page 2 of 2
THIS DRAWING IS THE EXCLUSIVE PROPERTY OF ROSENBERGER
HOCHFREQUENZTECHNIK GMBH WITHOUT THEIR CONSENT IT MAY
NOT BE REPRODUCED OR GIVEN TO THIRD PARTS.
Formblatt: TCC_FB_35 /04 2006/ 1.0
ISO – Projektion
Screw the hot wire into the centre contact with insulator.
Screw the ground wire into the centre contact without insulator.
Disassemble the connector body according above picture.
Electrical tape may help to keep the shield in position.
Fold back the shield on outer contact 1.
Screw the nut on the outer contact 2 with
t
ightening torque 10 Nm max..
Caution: DO NOT turn the outer contact 2 !
Cut the shield wires which are overcoming
the thread of outer contact 1.
Outer contact 1
I. 2 way power with shield II. Coax power cable
Screw the hot wire into the centre contact with insulator
Screw half of the shield into the centre contact
without insulator.
Screw the outer contact 1 on the connector head.
Tightening torque 3 Nm max..
Caution: DO NOT turn the connector head !
OK! Outer contact 2
NO!
insulator insulator
Screw the outer contact 2 on the outer contact 1 with
t
ightening torque 5 Nm max..
C
aution: DO NOT turn the outer contact 1 !
OK!
NO!
OK!
NO!
Electrical tape