Maida Development Company - sales@maida.com - (757) 723-0785
STANDARD MARKING
Minimum marking shall consist of an
abbreviated style designation and, when
space is available, the manufacturer’s
initials or company logo.
Example:
MDC
FV
14N201
Where:
MDC - Company Initials
FV - F
ail safe Varistor
14 - Diameter
N - Series Designation (FN
, FM, FE)
201 - Nominal DC Voltage Rating
(200VDC)
A manufacturing date code and/or
special markings are available upon
request.
Other safety agency designations are
included where applicable.
THERMALLY PROTECTED SERIES
INTRODUCTION
14 FN 201 K
1. Nominal Disk Diameter
14 – 14mm
20 – 20mm
25 – 25mm
2. Lead Configuration
FN – 2 leaded
FM – 3 leaded, fused on center lead
FE – 3 leaded, fused on outer lea d
3. AC Voltage Rating
Two significant figures plus nu mber
of zeroes that follow, i.e. 201 is 200 VDC
4. Varistor Voltage Range Tolerance
The Thermally Protected Series is designed for safe
disconnection of the varistor from the circuit due to
abnormal operating conditions. These components
consist of 2 or 3 leaded wire leads, a thermal
disconnect, and have nominal diameters of 14mm,
20mm, and 25mm. Voltage ranges from 60VAC-
750VAC with peak surge currents of 4.5kA/6kA
(14mm), 10kA (20mm), and 18kA (25mm).
STYLE DESIGNATION
The Maida Style Number is the typical means to
identify our components when ordered. The style
number identifies several parameters that are
important for the characteristics of the device. An
alternative ordering method, if known, is by our Item
Number.
The following example is the standard part
numbering system when ordering our Thermally
Protected Series components by the Maida Style
Number:
39
Typical
Maida Nominal Minimum Cap.
Style Size Marking
Number 10 x 1000 8 x 20 1 V rms
μ
sec
μ
sec
1 2 Vmin Vmax @1kHz
A B C D E F (mm) (AC) (DC) (J) (J) (A) (A) (V) (V) (V) (A) (pF)
14FE820K X 14
MDC-FV-14E820K
50 65 27 27 4500 2500 74 90 135 50 2400
14FM820K X 14
MDC-FV-14M820K
50 65 27 27 4500 2500 74 90 135 50 2400
14FN820K X 14
MDC-FV-14N820K
50 65 27 27 4500 2500 74 90 135 50 2400
20FE820K X 20
MDC-FV-20E820K
50 65 56 56 10000 6500 74 90 135 100 4900
20FM820K X 20
MDC-FV-20M820K
50 65 56 56 10000 6500 74 90 135 100 4900
20FN820K X 20
MDC-FV-20N820K
50 65 56 56 10000 6500 74 90 135 100 4900
14FE101K X 14
MDC-FV-14E101K
60 85 33 33 4500 2500 90 110 165 50 2000
14FM101K X 14
MDC-FV-14M101K
60 85 33 33 4500 2500 90 110 165 50 2000
14FN101K X 14
MDC-FV-14N101K
60 85 33 33 4500 2500 90 110 165 50 2000
20FE101K X 20
MDC-FV-20E101K
60 85 70 70 10000 6500 90 110 165 100 4000
20FM101K X 20
MDC-FV-20M101K
60 85 70 70 10000 6500 90 110 165 100 4000
20FN101K X 20
MDC-FV-20N101K
60 85 70 70 10000 6500 90 110 165 100 4000
14FE121K X 14
MDC-FV-14E121K
75 100 40 40 4500 2500 108 132 200 50 1700
14FM121K X 14
MDC-FV-14M121K
75 100 40 40 4500 2500 108 132 200 50 1700
14FN121K X 14
MDC-FV-14N121K
75 100 40 40 4500 2500 108 132 200 50 1700
20FE121K X 20
MDC-FV-20E121K
75 100 85 85 10000 6500 108 132 200 100 3300
20FM121K X 20
MDC-FV-20M121K
75 100 85 85 10000 6500 108 132 200 100 3300
20FN121K X 20
MDC-FV-20N121K
75 100 85 85 10000 6500 108 132 200 100 3300
14FE151K X 14
MDC-FV-14E151K
95 125 50 50 6000 4500 135 165 250 50 1300
14FM151K X 14
MDC-FV-14M151K
95 125 50 50 6000 4500 135 165 250 50 1300
14FN151K X 14
MDC-FV-14N151K
95 125 50 50 6000 4500 135 165 250 50 1300
20FE151K X 20
MDC-FV-20E151K
95 125 100 100 10000 6000 135 165 250 100 2700
20FM151K X 20
MDC-FV-20M151K
95 125 100 100 10000 6000 135 165 250 100 2700
20FN151K X 20
MDC-FV-20N151K
95 125 100 100 10000 6000 135 165 250 100 2700
25FE151K X 25
MDC-FV-25E151K
95 125 160 160 15000 12000 135 165 250 150 4300
25FM151K X 25
MDC-FV-25M151K
95 125 160 160 15000 12000 135 165 250 150 4300
25FN151K X 25
MDC-FV-25N151K
95 125 160 160 15000 12000 135 165 250 150 4300
14FE181K X 14
MDC-FV-14E181K
115 150 58 58 6000 4500 162 198 300 50 1100
14FM181K X 14
MDC-FV-14M181K
115 150 58 58 6000 4500 162 198 300 50 1100
14FN181K X 14
MDC-FV-14N181K
115 150 58 58 6000 4500 162 198 300 50 1100
20FE181K X 20
MDC-FV-20E181K
115 150 110 110 10000 6000 162 198 300 100 2200
20FM181K X 20
MDC-FV-20M181K
115 150 110 110 10000 6000 162 198 300 100 2200
20FN181K X 20
MDC-FV-20N181K
115 150 110 110 10000 6000 162 198 300 100 2200
25FE181K X 25
MDC-FV-25E181K
115 150 175 175 15000 12000 162 198 300 150 3500
25FM181K X 25
MDC-FV-25M181K
115 150 175 175 15000 12000 162 198 300 150 3500
25FN181K X 25
MDC-FV-25N181K
115 150 175 175 15000 12000 162 198 300 150 3500
14FE201K X 14
MDC-FV-14E201K
130 170 70 70 6000 4500 185 225 340 50 1000
14FM201K X 14
MDC-FV-14M201K
130 170 70 70 6000 4500 185 225 340 50 1000
14FN201K X 14
MDC-FV-14N201K
130 170 70 70 6000 4500 185 225 340 50 1000
20FE201K X 20
MDC-FV-20E201K
130 170 140 140 10000 6000 185 225 340 100 2000
20FM201K X 20
MDC-FV-20M201K
130 170 140 140 10000 6000 185 225 340 100 2000
20FN201K X 20
MDC-FV-20N201K
130 170 140 140 10000 6000 185 225 340 100 2000
25FE201K X 25
MDC-FV-25E201K
130 170 210 210 15000 12000 185 225 340 150 3200
25FM201K X 25
MDC-FV-25M201K
130 170 210 210 15000 12000 185 225 340 150 3200
25FN201K X 25
MDC-FV-25N201K
130 170 210 210 15000 12000 185 225 340 150 3200
14FE221K X 14
MDC-FV-14E221K
140 180 78 78 6000 4500 198 242 360 50 900
14FM221K X 14
MDC-FV-14M221K
140 180 78 78 6000 4500 198 242 360 50 900
14FN221K X 14
MDC-FV-14N221K
140 180 78 78 6000 4500 198 242 360 50 900
20FE221K X 20
MDC-FV-20E221K
140 180 155 155 10000 6000 198 242 360 100 1800
20FM221K X 20
MDC-FV-20M221K
140 180 155 155 10000 6000 198 242 360 100 1800
20FN221K X 20
MDC-FV-20N221K
140 180 155 155 10000 6000 198 242 360 100 1800
25FE221K X 25
MDC-FV-25E221K
140 180 230 230 15000 12000 198 242 360 150 2900
25FM221K X 25
MDC-FV-25M221K
140 180 230 230 15000 12000 198 242 360 150 2900
25FN221K X 25
MDC-FV-25N221K
140 180 230 230 15000 12000 198 242 360 150 2900
NOTES:
Appendix A lists the single-pulse peak current and energy ratings on file with the Safety Agencies.
Maximum transient rating specified in this table are valid. They may differ from those shown in Appendix A.
A = UL1449 D = VDE
B = cUL E =
C = CSA F =
Continuous Transient
Varistor ClampingPeak
50VAC thru 140VAC VARISTORS
Recognitions
Energy
8 x 20
μ
sec
Maximum Ratings Electrical Characteristics
Max
Voltage
Agency # Pulses
Safety @1 mA DC (@Test Current)
THERMALLY PROTECTED SERIES
SPECIFICATIONS
VoltageVoltage To CurrentApplied
Standards
(
8 x 20
μ
sec
)
40