810008925/DB810008925/DB
||
BB
--
024024
--LNLN--8W8W--F12NS/16GF12NS/16G
LightScope ZWP® Blown Micro Single Jacket All-Dielectric Outdoor Stranded Loose
Tube Arid
-Core®
Construction Cable
Product Classification
Portfolio
CommScope®
Product Type
Fiber OSP cable
Regional Availability
Asia | Australia/New Zealand | EMEA | Latin America | North America
Standards And Qualifications
Cable Qualification Standards
IEC 60794
-
5
-
10
Representative Image
General Specifications
Cable Type
Stranded loose tube
Construction Type
Non
-
armored
Subunit Type
Gel
-
filled
Construction Materials
Fiber Type Solution
G.652.D and G.657.A1
Jacket Material
High density polyethylene (HDPE)
Total Fiber Count
24
Fiber Type
G.652.D and G.657.A1
Fiber Type, quantity
24
Fibers per Subunit, quantity
12
Jacket Color
Black
Jacket UV Resistance
UV stabilized
Dimensions
Buffer Tube/Subunit Diameter
1.60 mm | 0.06 in
Cable Weight
20.0 kg/km | 14.0 lb/kft
Product SpecificationsProduct Specifications
©©2018CommScope, Inc. All rights reserved. All trademarks identified by 2018CommScope, Inc. All rights reserved. All trademarks identified by ® ® or ™ are registered trademarks, respectively, of CommScope.or ™ are registered trademarks, respectively, of CommScope.
All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: February 22, 2018All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: February 22, 2018
page 1 of 3page 1 of 3
March 28, 2018March 28, 2018
Diameter Over Jacket
5.50 mm | 0.22 in
Filler, quantity
3
Subunit, quantity
2
Physical Specifications
Minimum Bend Radius, loaded
8.2 cm | 3.2 in
Minimum Bend Radius, unloaded
5.5 cm | 2.2 in
Tensile Load, long term, maximum
97 N | 22 lbf
Tensile Load, short term, maximum
324 N | 73 lbf
Vertical Rise, maximum
492.0 m | 1614.2 ft
Environmental Specifications
Environmental Space
Air
-
blown, microduct
Installation Temperature
-
30 °C to +70 °C (
-
22 °F to +158 °F)
Operating Temperature
-
30 °C to +70 °C (
-
22 °F to +158 °F)
Storage Temperature
-
30 °C to +75 °C (
-
22 °F to +167 °F)
Mechanical Test Specifications
Compression
10 N/mm
Compression Test Method
FOTP
-
41 | IEC 60794
-
1 E3
Flex
25 cycles
Flex Test Method
FOTP
-
104 | IEC 60794
-
1 E6
Impact
0.30 N
-
m | 0.22 ft lb
Impact Test Method
FOTP
-
25 | IEC 60794
-
1 E4
Strain
See long and short term tensile loads
Strain Test Method
FOTP
-
33 | IEC 60794
-
1 E1
Twist
10 cycles
Twist Test Method
FOTP
-
85 | IEC 60794
-
1 E7
Water Penentration
24 h
Water Penentration Test Method
FOTP
-
82 | IEC 60794
-
1 F5
Environmental Test Specifications
Cable Freeze
-
2 °C | 28 °F
Cable Freeze Test Method
FOTP
-
98 | IEC 60794
-
1 F15
Drip
70 °C | 158 °F
Drip Test Method
FOTP
-
81 | IEC 60794
-
1 E14
Heat Age
-
30 °C to +85 °C (
-
22 °F to +185 °F)
Heat Age Test Method
IEC 60794
-
1 F9
Low High Bend
-
30 °C to +60 °C (
-
22 °F to +140 °F)
Low High Bend Test Method
FOTP
-
37 | IEC 60794
-
1 E11
Temperature Cycle
-
30 °C to +70 °C (
-
22 °F to +158 °F)
Temperature Cycle Test Method
FOTP
-
3 | IEC 60794
-
1 F1
Regulatory Compliance/Certifications
Product SpecificationsProduct Specifications
810008925/DB|B810008925/DB|B
--
024024
--
LNLN
--
8W8W
--
F12NS/16GF12NS/16G
©©2018CommScope, Inc. All rights reserved. All trademarks identified by 2018CommScope, Inc. All rights reserved. All trademarks identified by ® ® or ™ are registered trademarks, respectively, of CommScope.or ™ are registered trademarks, respectively, of CommScope.
All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: February 22, 2018All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: February 22, 2018
page 2 of 3page 2 of 3
March 28, 2018March 28, 2018