Specifications
identiFINDER S900
Technology Autonomous radiation sensor
Product Variants 203.2-NG
1
, 203.2-NGH
2
, 303.1-NG
3
, 303.1-NGH
4
, 403.3-NG
5
, 403.3-NGH
6
, 416.1-
NG
7
, 416.1-NGH
8
Gamma (Nal) 2.0 x 3.0in (51 x 76mm); 2.0 x 4.0 x 16.0in (51 x 102 x 406mm)
7,8
Gamma (High Dose Rate) Energy compensated Geiger-Müller detector
Neutrons (He-3 PCT) 0.7 x 4.2in (19 x 106mm)
2,8
; 0.75 x 3.0in (19.05 x 76.2mm)
4,6
Energy Range (Gamma) 20 keV - 3 MeV
Throughput >100 kcps
Max. Input Count Rate 300 kcps
Dose Rate Range
1-2, 5-6
0.01 µµSv/h – 1 Sv/h (1.0 µrem/h – 100 rem/h)
Dose Rate Range
3-4, 7-8
0 µSv/h – 1 Sv/h (0 µrem/h – 100 rem/h)
Gamma Spectrum 1024 channels; 3 MeV
Dose Rate / Accuracy 50 keV - 1500 keV; ±30 %
Scintillator Operating Range
1-6
0 µSv/h – 100 Sv/h (0 rem/h – 10 mrem/h)
Scintillator Operating Range
7-8
0 µSv/h – 20 Sv/h (0 rem/h – 2.0 mrem/h)
Geiger-Müller Operating Range
1-6
100 µSv/h – 10 mSv/h (10 mrem/h – 1.0 rem/h)
Geiger-Müller Operating Range
7-8
20 µSv/h – 10 mSv/h (2.0 mrem/h – 1.0 rem/h)
Overload Threshold 10 mSv/h – 1 Sv/h (1.0 rem/h – 100 rem/h)
Neutron Sensitivity
2, 4, 6, 8
11 cps/nv; ±20 % thermal neutrons
Stabilization K-40 calibration source and LED
Typical Resolution ≤8 % FWHM at 662 keV
Service Interval Recommended 2 year service interval
Sampling & Analysis
Sample Introduction Absorption of EM gamma or neutron emissions
Threats Detects neutron or gamma radiation emitted from natural
occurrences in the environment, special nuclear material,
industrial, or medical material
Sampling & Analysis From a few seconds to minutes
System Interface
Display & Alerts identiFINDER S900 Data Protocol for network integration
Communication Ethernet RJ45, 10 Mbit/s, 100 Mbit/s
Embedded Software Windows
®
CE operating system
Training Requirements <10 mins for operator; 1/2 day for advanced user
Power
Input Voltage DC 12V, 3W
1-2, 5-8
; Power over Ethernet (PoE)
1-8
Cold Start Time 15 mins from cold start
Environmental
Operating Temp -4 to 122 °F (-20 to 50 °C)
Operating Humidity 10 to 80%, non-condensing
Storage Temp -22 to 158 °F (-30 to 70 °C)
Physical Features
Dimensions (HxDia.) / Weight
1-2
25.8 x 2.5 in (654 x 63 mm) / 5.3 lb (2.4 kg)
Dimensions (HxDia.) / Weight
3-4
Tube: 35.9 x 2.5 in (911 x 63 mm) / 6.8 lb (3.1 kg)
Foot: 14.7 x 2.4 in (373 x 61 mm) / 22.0 lb (10.0 kg)
Dimensions (HxDia.) / Weight
5-6
29.1 x 5.5 in (740 x 140 mm) / 17.6 lb (8.0 kg)
Dimensions (HxWxD) / Weight
7-8
35.9 x 8.6 x 6.8 in (911 x 218 x 173 mm) / 46.3 lb (21.0 kg)
Enclosure & Protection Aluminium
1, 2 ,7, 8
; PVC-U
5, 6
; black steel
3,4
connection belt
compatible with Tensabarrier and BelTrac; protection ratings
IP54
1-4
, IP55
5-6
, IP62
7-8