ESD Protector
Overvoltage Protection Device
PRODUCT: PESD0402-240
DOCUMENT: SCD28721
REV LETTER: C
REV DATE: JULY 26, 2016
PAGE NO.: 1 OF 9
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised July 26, 2016
Specification Status: RELEASED
BENEFITS
ESD protection for high frequency applications (HDMI 1.3)
Smaller form factor for board space savings
Helps protect electronic circuits against damage from electrostatic discharge (ESD) events
Assists equipment to pass IEC 61000-4-2, level 4 testing
FEATURES
0.25 pF (typ) Capacitance
Low leakage current
Low clamping voltage
Fast response time (<1ns)
Capable of withstanding numerous ESD strikes
Compatible with standard reflow installation procedures
Thick film technology
Bi-directional protection
APPLICATIONS
HDMI 1.3 interface
LCD, HDTV
Cellular phones
Antennas (cell phones, GPS…)
Portable video devices (PDA, DSC, Bluetooth…)
Printer ports
High speed Ethernet
USB 2.0 and IEEE 1394 interfaces
DVI interface
MATERIALS INFORMATION
RoHS Compliant ELV Compliant Halogen Free* Lead Free
CAUTION: This device should not be used in Power Bus applications
HF
ESD Protector
Overvoltage Protection Device
PRODUCT: PESD0402-240
DOCUMENT: SCD28721
REV LETTER: C
REV DATE: JULY 26, 2016
PAGE NO.: 2 OF 9
© 2016 Littelfuse, Inc.
Specifications are subject to change without notice.
Revised July 26, 2016
PART NUMBERING
PESD 0402 - 240
Series Operating Voltage Designator
24 x 10
0
= 24V
DC
EIA Size
* Halogen Free refers to: Br900ppm, Cl900ppm, Br+Cl1500ppm
TYPICAL DEVICE RATINGS AND CHARACTERISTICS
Continuous
Max
Operating
Voltage
Typical TLP
Clamping
Voltage
1
after 30ns
Typical
Capacitance
2
@ 1 MHz,
1V
rms
Typical
Leakage
Current
@24V
DC
Symbol
V
DC
V
C(TLP 30)
Cp
I
L(Typ)
Unit
V
V
pF
μA
Value
24
40
0.25
<0.01
Note 1: TLP test method at 1000V (refer to FIG. 5 on page 5)
Note 2: Typical capacitance @ 0V and 24V bias
GENERAL CHARACTERISTICS
Operating temperature: -55°C to +125°C
Storage temperature: -55°C to +125°C
ESD voltage capability (tested per IEC 61000-4-2)
o Contact discharge mode: 8kV (typ), 15kV (max)
o Air discharge mode: 15kV (typ), 25kV (max) [1 pulse: per customer request]
ESD pulse withstand: Typically 100 pulses (tested per IEC 61000-4-2, level 4, and contact method)
Environmental Specifications
Bias Humidity
Test
Thermal Shock
Bias Heat
Test
Bias Low
Temp Test
Solderability
Solder
Heat
Vibration
Mechanical
Shock
Solvent
Resistan
ce
Test
Conditions
@ 85
o
C
@ 85% RH
V
DC
(max)
1000 hours
-55
o
C to 125
o
C
30min dwell
1000 cycles
@ 125
o
C
V
DC
(max)
1000 hours
@ -55
o
C
V
DC
(max)
1000 hours
250
o
C +/- 5
o
C
3s +/- 1s
260
o
C,10s
10 to 50Hz, 60s
cycle, 2hrs
each in X-Y-Z
axis
1500G,
0.5ms, X-
Y-Z axis
3 times
IPA
ultrasonic
300s