PRESSURE | LOAD | TORQUE | POSITION | ROTARY ANGLE | TILT | ACCELERATION | VIBRATION | RATE | SIGNAL CONDITIONER | DATALOGGER
PC420-EX
Explosion Proof Vibration Transmitter
Measurement range: 5 g to 20 g (acceleration)
0.5 ips to 50 ips (velocity)
Repeatability 2 %
Frequency range (±3 dB): 4 … 2000 Hz
Temperature range: -40 … +85 °C
Features
Acceleration or velocity output units
True root-mean-square (RMS), equivalent
peak or true peak output
Explosion proof certification (ATEX, CSA)
Corrosion resistant
ESD, overload and reverse wiring protection
Benefits
Choice of RMS, true peak or peak output
allows you to choose the sensor that best fits
your requirements
Provides continuous trending of overall
machine vibration
Can help guide maintenance in prioritizing the
need for service
Helps notify of impending equipment failure
The 4-20 mA output of this sensor series is proportional to the overall vibration. An output of 4 mA indicates
no vibration; a level of 0 ips for velocity output models; a level of 0 g for acceleration output models. A full-
scale reading of 20 mA indicates that the maximum range (RMS or peak) of vibration is present. The peak
output units provide a computed equivalent peak level of vibration based on the RMS.
Specifications
Dynamic specifications
Full scale, 20 mA ±5 %: see table 1
Frequency range: ±10 %
±3 dB
10 … 1000 Hz
4 … 2000 Hz
Repeatability: ±2 %
Transverse sensitivity, max.: 5.0 %
Electrical specifications
Supply voltage
(at sensor terminals):
14 … 30 VDC
Loop resistance
(at 24 VDC), max.:
700
Turn on time, 4 … 20 mA loop <10 s
Grounding:
Case isolated, internally
shielded
Environmental specifications
Operating temperature range: -40 … +85 °C
Vibration limit: 250 g peak
Destruction limit: 2500 g peak
Environmental sealing: Epoxy sealed
Physical data
Sensing element design: PZT ceramic, shear
Weight: 380 grams
Case material: Stainless steel 303
Mounting: Tapped hole 3/8-24 x 3/8
Cable: Leads 18 AWG, 4 m
Explosion Proof Certification
CSA
PC420Axx-yy-EX
Class 1, Division 1,
Groups A, B, C, D
PC420Vxx-yy-EX
Class 1, Division 1, 2,
Groups A, B, C, D
ATEX
PC420Axx-yy-EX
EEx d IIC T3C
EEx nA IIC T3C
PC420Vxx-yy-EX
Ga EEx d IIC T3
EEx nA IIC T3C
For hazardous area locations, sensor must be installed in
accordance with installation instructions or local code
requirements.
Notes:
(1) maximum loop resistance (RL) can be calculated by:
R
L
(max. resistance) = (V
DC power
- 10 V) / 20 mA
DC Supply
voltage
R
L
(max. resistance)
2
R
L
(min. wattage capability)
3
12 VDC 100 W
20 VDC 500 ¼ W
24 VDC 700 ½ W
26 VDC 800 ½ W
30 VDC 1.0 k ½ W
(2) Lower resistance is allowed, greater than 10 recommended
(3) Minimum R
L
wattage determined by: (0.0004 x R
L
)
PC420-EX-en, © ALTHEN GmbH 11/2
012, rev. 1.01 Page 1/2
ALTHEN GmbH Mess- und Sensortechnik
Frankfurter Str. 150 - 152
65779 Kelkheim / Germany
+49 6195 70060
+49 6195 700666
http://www.althensensors.com
info@althen.de
Table 1: Part Number Configuration PC420xx-yy-EX
xx (output 4… 20 mA) -yy (Full Scale Range)
Acceleration: Velocity:
AR = Acceleration, RMS -05 = 5 g (49 m/s²) -05 = 0.5 ips (12.8 mm/s)
AP = Acceleration, equivalent peak -10 = 10 g (98 m/s²) -10 = 1.0 ips (25.4 mm/s)
ATP = Acceleration, true peak -20 = 20 g (196 m/s²) -20 = 2.0 ips (50.8 mm/s)
VR = Velocity, RMS -30 = 3.0 ips (76.2 mm/s)
VP = Velocity, equivalent peak -50 = 5.0 ips (127 mm/s)
VTP = Velocity, true peak
Dimensions
Dimensions in in
ches (mm), approx. values
These drawings are for information only and not intended for engineering.
Please contact us for detailed drawings.
Wiring
Connector Pin Function
Red Loop positive (+)
White Loop negative (-)
Due to continued product development, ALTHEN and partners reserve the right to vary the foregoing details without prior notice.
PC420-EX-en, © ALTHEN GmbH 11/2012, rev. 1.01 Page 2/2
ALTHEN GmbH Mess- und Sensortechnik
Frankfurter Str. 150 - 152
65779 Kelkheim / Germany
+49 6195 70060
+49 6195 700666
http://www.althensensors.com