Installation Instructions for the
TruStability
®
Board Mount Pressure Sensors
TSC Series, Compensated/Unamplified
±60 mbar to ±10 bar | ±6 kPa to ±1 MPa | ±1 psi to ±150 psi
Millivolt Analog Output
NSC Series, Uncompensated/Unamplified
±2.5 mbar to ±10 bar | ±250 Pa to ±1 MPa | ±1 inH
2
O to ±150 psi
Millivolt Analog Output
Issue 5
50063864
Honeywell’s TruStability
®
TSC Series and NSC Series are
piezoresistive silicon pressure sensors offering a ratiometric analog
output for reading pressure over the specified full scale pressure
span and temperature range.
TSC Series:
•Temperaturecompensatedandunamplified.
•Compensationmakesiteasiertointegratethesensorintoa
system by eliminating the need to calibrate the system over
temperature and also offers reduced part-to-part variation.
•Compensatedtemperaturerangeis0°Cto85°C[-32°Fto
185°F].
•Operatingtemperaturerangeis-40°Cto85°C[-40°Fto
185°F].
•Measuresdifferentialorgagepressures
NSC Series:
•Uncompensatedandunamplified.
•Allowscustomerstheflexibilityofperformingtheirown
calibration while still benefiting from the industry-leading
stability, accuracy, and repeatability that the Honeywell
TruStability
®
Pressure Sensors provide.
•Operatesasspecifiedfrom-40°Cto85°C[-40°Fto185°F].
•Measuresabsolute,differentialorgagepressures.
The absolute versions have an internal vacuum reference and an
output value proportional to absolute pressure. Differential versions
allow measurement of pressure between two pressure ports. Gage
versions are referenced to atmospheric pressure and provide an
output proportional to pressure variations from atmosphere.
The TSC Series and NSC Series sensors are intended for use with
non-corrosive, non-ionic gases, such as air. Port 1 can also be used
fornon-corrosive,non-ionicliquidsonsensorsratedabove60mbar
|6kPa|1psi.
TheTSCandNSCSeriesoffernumerouspackagestylesand
mountingoptions,makingiteasierfordevicemanufacturersto
integrate the product into their applications. These sensors offer
infiniteresolutiononthepressuresignal.Frequencyresponseis
alsotypicallylimitedonlybytheenduser’ssystem.Allproductsare
designedandmanufacturedaccordingtoISO9001.
Table 1. Absolute Maximum Ratings
1
Characteristic Min. Max. Unit
Supply voltage (V
supply
)
2
:
pressure ranges >60mbar|6kPa|1psi
pressure ranges <40mbar|4kPa|20inH
2
O
-12.0
0
12.0
7
Vdc
Storage temperature -40[-40] 85[185] °C[°F]
Soldering time and temperature:
lead solder temperature (SIP, DIP)
peakreflowtemperature(SMT)
4smax.at250°C[482°F]
15smax.at250°C[482°F]
1
Absolutemaximumratingsaretheextremelimitsthedevicewillwithstandwithoutdamage.
2
Incorrect application of supply voltage or ground to the wrong pin may cause electrical failure.
2 Honeywell Sensing and Control
TSC Series, Compensated/Unamplified
NSC Series, Uncompensated/Unamplified
Issue 5
50063864
Table 2. Operating Specifications
Characteristic
Min. Typ. Max. Unit
Supply voltage (V
supply
):
1,2
pressure ranges >60mbar|6kPa|1psi
pressure ranges <40mbar|4kPa|20H
2
O
1.5
2.7
5.0
5.0
12.0
6.5
Vdc
Supplycurrent(at5.0Vdcsupply)
TSC Series
NSC Series
0.6
1.5
1
2.2
mA
Operatingtemperaturerange
3
-40[-40] 85[185] °C[°F]
Compensated temperature range
4
0[32] 85[185] °C[°F]
Startup time 5 ms
TSC Series output resistance 2.5 kOhm
1
Ratiometricity of the sensor (the ability of the device output to scale to the supply voltage) is achieved within the specified operating voltage.
2
Incorrect application of supply voltage or ground to the wrong pin may cause electrical failure.
3
Operatingtemperaturerange:Thetemperaturerangeoverwhichthesensorwillproduceanoutputproportionaltopressure.
4
Compensated temperature range: The temperature range over which the sensor will produce an output proportional to pressure within the specified perfor-
mance limits.
Table 3. Environmental Specifications
Characteristic
Parameter
Humidity 0%to95%RH,non-condensing
Vibration MIL-STD-202F,Method214A,Condition1E(15g,10Hzto2kHz)
Shock MIL-STD-202F,Method213B,ConditionF(100g,6msduration)
Life
1
1 million pressure cycles minimum
Solder reflow J-STD-020-DMSL1(unlimitedshelflifewhenstoredatlessthan30°Cand85%RH)
1
Life may vary depending on the specific application in which the
sensor is utilized.
Table 4. Wetted Materials
1
Component
Port 1
(Pressure Port)
Port 2
(Reference Port)
Ports and covers
high temperature
polyamide
high temperature
polyamide
Substrate alumina ceramic alumina ceramic
Adhesives epoxy,RTV epoxy,RTV
Electronic
components
silicon silicon, glass, gold
1
Contact Honeywell Customer Service for detailed material information.
CAUTION
PRODUCT DAMAGE
Ensure liquid media is applied to Port 1 only; Port 2 is not
compatible with liquids.
• Ensure liquid media contains no particulates. All
TruStability® sensors are dead-ended devices. Particulates
can accumulate inside the sensor, causing damage or
affecting sensor output.
• Recommend that the sensor be positioned with Port 1 facing
downwards; any particulates in the system are less likely
to enter and settle within the pressure sensor if it is in this
position.
• Ensure liquid media does not create a residue when dried;
build-up inside the sensor may affect sensor output.
Rinsing of a dead-ended sensor is difcult and has limited
effectiveness for removing residue.
• Ensure liquid media are compatible with wetted materials.
Non-compatible liquid media will degrade sensor
performance and may lead to sensor failure.
Failure to comply with these instructions may result in
product damage.