1 Affected Products
Product Name
Order Number
Type No
Application firmware
SARA-G340
SARA-G340-02S
SARA-G340-02S-00
A00.02
SARA-G350
SARA-G350-02S
SARA-G350-02S-00
A00.02
2 Type of Change
[ x ] Hardware modification
[ x ] Firmware update
[ x ] Documentation update
3 Description of Change
Firmware
o Implementation of various new firmware features and improvements
Hardware
o Implementation of new memory
o Implementation of a new power amplifier (SARA-G340 only)
Module thickness reduction to 2.4 mm
o Separation of digital and RF power supply
See Appendix A for detailed description of the changes.
4 Schedule
Production parts are already available.
5 Customer Impact and Recommended Action
5.1 System Test
u-blox has taken utmost care to achieve the highest level of backward compatibility of SARA-G340-02S and
SARA-G350-02S to its predecessors. A system test is however recommended.
Depending on the type of application and required certification schemes, a delta certification may apply. We
recommend consulting with your preferred notified body to verify the actual requirements applicable to your
product
5.2 Previous SARA-G versions
The previous versions of SARA-G340 and SARA-G350 can still be ordered by customers who want to use the
older version, although the migration to the latest SARA-G350/SARA-G340 version is recommended:
UBX-16001074 IN Information Note SARA-G340-02S/SARA-G350-02S Release to production
Page 2 of 4
locate, communicate, accelerate
6 Reference Documents
[1] u-blox AT-commands Manual, u-blox document UBX-13002752
[2] SARA-G3 Series Data-sheet, u-blox document UBX-13000993
[3] SARA-G3 Series System Integration Manual, u-blox document UBX-13000995
Remark: it is not possible to upgrade previous SARA-G350 and SARA-G340 versions to the latest 08.90 A00.02
firmware.