Technical Application Note September 2014 www.eaton.com
5. Leave the DTR setting at the default, AT&D0.
This setting ignores the DTR. The DTR control is used
by the client to establish a connection to the server.
Because this modem is selected as a server, DTR can
be left at the default setting, which ignores the DTR.
6. Under the External PAD Settings, select Server as the
PAD Mode, and select TCP as the PAD Protocol.
7. In the Incoming Friendly IP Address field, enter the
cellular IP address of the remote modem (the serial
client).
You can find the cellular IP address of the remote
modem by logging onto its Web interface and
displaying the Unit Status page.
8. In the Incoming Port field, enter the TCP port to be
used.
Both the serial server and serial client must use the
same TCP port. Port 5002 is used in this example.
9. Click Save.
Serial Server Configuration
Configuring the 615M-1 serial client
Use this procedure to configure the remote 615M-1 modem
as the serial client that will establish the connection to the
serial server.
1. Log onto the Web interface of the remote 615M-1
modem.
2. On the menu, click Serial.
3. For the Electrical Interface setting, select RS-232.
4. Set the baud rate, data/stop bits, and parity to suit your
application.
The settings used in this example are 9600, 8, 1, N.
5. Set the DTE as follows:
This application example demonstrates two PCs
connecting their terminal sessions together. There are
two types of serial communication devices, DTE and
DCE. PCs are DTE devices, which means by default the
DTR line (pin 4) is ON.
• For DTE devices, select AT&D9 from the DTR
drop-down menu. The modem connects to the
server when DTR is ON. When DTR is OFF, the
modem does not connect or the connection will
close if in session.
• For DCE devices, such as other modems or ELPRO
115S modules, DTR is OFF by default. For these
devices, select AT&D8 from the DTR drop-down
menu. The modem connects when DTR is OFF and
disconnects when DTR is ON.
For more information, see the Help link on the Serial
Web page.
6. Under External PAD Settings, select Client as the PAD
Mode, and select TCP as the PAD Protocol.
7. In the Outgoing Port field, set the outgoing port to
match the incoming port of the serial server.
Both the serial server and serial client must use the
same TCP port. Port 5002 is used in this example.
8. In the Remote Host IP Address field, enter the cellular
IP address of the serial server.
You can find cellular IP address of the serial server by
logging on to its Web interface and displaying the Unit
Status page.
9. For TCP Client Keep Alive, select the Enabled option.
When this option is enabled, an “alive” packet is
periodically sent from the client to the server in order to
detect a broken connection. The modem automatically
tries to re-establish the connection if necessary.
10. Click Save.