AL4RPVAL4RPV--
5050
AL4RPV-50, HELIAX®
Plenum Rated Air Dielectric Coaxial Cable, corrugated aluminum,
1/2 in, off white PVDF jacket
l This product is part of the CommScope Wired for Wireless® Solution
Product Classification
Brand
HELIAX®
Product Series
AL4
-
50
Product Type
Air coaxial cable
Construction Materials
Jacket Material
PVC
Dielectric Material
PE spline
Flexibility
Standard
Inner Conductor Material
Copper
-
clad aluminum wire
Jacket Color
Off
-
white
Outer Conductor Material
Corrugated aluminum
Dimensions
Nominal Size
1/2 in
Cable Weight
0.21 kg/m | 0.14 lb/ft
Diameter Over Jacket
15.748 mm | 0.620 in
Inner Conductor OD
4.5720 mm | 0.1800 in
Outer Conductor OD
14.046 mm | 0.553 in
Electrical Specifications
Cable Impedance
50 ohm
±
2 ohm
Capacitance
76.0 pF/m | 23.0 pF/ft
dc Resistance, Inner Conductor
1.570 ohms/km | 0.480 ohms/kft
dc Resistance, Outer Conductor
1.570 ohms/km | 0.480 ohms/kft
dc Test Voltage
4000 V
Inductance
0.190 µH/m | 0.058 µH/ft
Insulation Resistance
100000 Mohms
km
Jacket Spark Test Voltage (rms)
5000 V
Operating Frequency Band
1 6000 MHz
Peak Power
40.0 kW
Power Attenuation
2.325
Pulse Reflection
0.5%
Velocity
88%
Environmental Specifications
Installation Temperature
-
5 °C to +60 °C (+23 °F to +140 °F)
Operating Temperature
-
20 °C to +85 °C (
-
4 °F to +185 °F)
Storage Temperature
-
20 °C to +85 °C (
-
4 °F to +185 °F)
Product SpecificationsProduct Specifications
©©2018CommScope, Inc. All rights reserved. All trademarks identified by 2018CommScope, Inc. All rights reserved. All trademarks identified by ® ® or ™ are registered trademarks, respectively, of CommScope.or ™ are registered trademarks, respectively, of CommScope.
All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: November 10, All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: November 10,
20172017
page 1 of 4page 1 of 4
January 22, 2018January 22, 2018
General Specifications
Brand
HELIAX®
Ordering Note
CommScope® standard product (Global)
Mechanical Specifications
Bending Moment
6.8 N
-
m | 5.0 ft lb
Fire Retardancy Test Method
NFPA 262/CATVP/CMP
Flat Plate Crush Strength
1.4 kg/mm | 80.0 lb/in
Minimum Bend Radius, Multiple Bends
127.00 mm | 5.00 in
Minimum Bend Radius, Single Bend
64.00 mm | 2.50 in
Number of Bends, minimum
15
Tensile Strength
79 kg | 175 lb
Note
Performance Note
Values typical, unless otherwise stated
Standard Conditions
Attenuation, Ambient Temperature
20 °C | 68 °F
Average Power, Ambient Temperature
40 °C | 104 °F
Average Power, Inner Conductor Temperature
100 °C | 212 °F
Return Loss/VSWR
VSWR
Return Loss (dB)
1.13
24.30
1.13
24.30
1.13
24.30
Product SpecificationsProduct Specifications
AL4RPVAL4RPV
--
5050
©©2018CommScope, Inc. All rights reserved. All trademarks identified by 2018CommScope, Inc. All rights reserved. All trademarks identified by ® ® or ™ are registered trademarks, respectively, of CommScope.or ™ are registered trademarks, respectively, of CommScope.
All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: November 10, All specifications are subject to change without notice. See www.commscope.com for the most current information. Revised: November 10,
20172017
page 2 of 4page 2 of 4
January 22, 2018January 22, 2018