© 2015 Glenair, Inc • 1211 Air Way, Glendale, CA 91201 • 818-247-6000 • www.glenair.com • U.S. CAGE code 06324 • BacNav OFS
Dimensions in Inches (millimeters) are subject to change without notice.
SERIES 390
BacNav™ OFS
Assembly Instructions
3/8" ±1/8" (Electrical)
1/2" ±1/8" (Fiber-optic)
Calculate Length
For Contact
Termination
To Rear Of
Connector Shell
Connector-coupling-nut
Engagement Length
Main Body Assembly
Overall Length
Eective Main Body
Assembly Length
Connector
Length
The Following suggested assembly procedure serves as a guide for proper assembly and installation of Glenair P/N 390G084
Compression-nut and
Main Body
Assembly
Loosen with 7/64” Hex-Wrench
to Reposition Angle
O-ring
(If Applicable)
(If Applicable)
Braid/Kevlar® Folded
Back Flat Over Cable
Tape
Contacts/OFC's
Step 1
Cut cable to desired length, making sure to include contact
termination length and desired service loop length (Note:
service loop not applicable for ber termination.)
Step 2
Slide BacNav OFS backshell assembly onto cable-end being
terminated. Slide insert-retainer and o-ring or adapter (as
applicable) onto cable following the backshell. (Note: Adapter
may be coupled to backshell.) Unscrew and separate intermediate
compression nut and gland assembly from main body assembly.
(See gure 1)
Step 3
Prepare cable end for termination.
a. Determine cable jacket strip length. For precise
determination, it is recommended to terminate a connector
using a minimum strip length, then mark the cable jacket
at the required distance behind the main body assembly.
Length will include contact termination length, desired
service loop length (not applicable for ber) and eective
main body assembly length (includes installed adapter
length if present). (See gure 2)
b. Remove outer cable jacket exposing cable-shield (braid) or
Kevlar® strength members (ber-optic applications).
c.
Shielded electrical cable applications: Remove any water-
block material from cable-shield. Trim cable shield to 3-4
inch length (optional) then fold back at over outer cable
jacket and tape down.
Fiber-optic applications: Leave Kevlar® strength members
long, fold back over outer cable jacket and tape down
(See gure 3)
Assembly Overview
Fig. 1
Fig. 2
Fig. 3