Composite
Backshells
A-66
GLENAIR, INC. 1211 AIR WAY GLENDALE, CA 91201-2497 818-247-6000 FAX 818-500-9912
© 2009 Glenair, Inc. Printed in U.S.A.
CAGE Code 06324
www.glenair.com
E-Mail: sales@glenair.com
A
B
C
D
E
F
G
REV 22 NOVEMBER 2013
Connector
Series 390 (Single Shield) EMI/RFI
Environmental Backshell
Assembly Instructions
A
2.00
(50.8)
B
(6) 600-157
Stainless Steel Composite
Hex Coupling Wrench
(7) Plug and Receptacle
Holding Tools
for 1/4" and 3/8" Socket
(8) 600-161
Hand Held Digital
Torque Wrench
Series 390 (Single Shield) EMI/RFI Environmental
Assembly Instructions
Backshell (1)
Strain Relief
Clamp (5)
Cable Sealing
O-Ring (4)
Adapter (3)
Ground
Ring (2)
COMPOSITE COUPLING
TORQUE VALUES
Shell Size
Reference
Composite
Torque
(Inch-Pounds)
08/09 35
10/11 35
12/13 40
14/15 40
16/17 40
18/19 40
20/21 80
22/23 80
24/25 80
28 120
32 120
36 120
Composite
Backshells
A-67
GLENAIR, INC. 1211 AIR WAY GLENDALE, CA 91201-2497 818-247-6000 FAX 818-500-9912
© 2009 Glenair, Inc. Printed in U.S.A.
CAGE Code 06324
www.glenair.com
E-Mail: sales@glenair.com
A
B
C
D
E
F
G
REV 22 NOVEMBER 2013
The following suggested procedure serves as a guide for proper assembly and installation of
straight Glenair Series 390 EMI/RFI Cable Sealing Backshells for use with jacketed cables and
a single overall EMI shield. It is recommended that trial samples of appropriate cables be used
to determine proper trim dimensions of the cable jacket, individual conductors and shielding.
NOTE: As with any electrical connector assembly procedure, be sure to use the proper
tools. For convenient reliable assembly of the connector and backshell, it is suggested
that Glenair's connector holding tools, strap wrenches and connector pliers be used.
1. Temporarily assemble backshell (1) to connector.
2. Place the ground ring (2), adapter, o-ring seal (plus washer if provided) and strain relief
clamp on the cable in the sequence shown. You are staging these components on the cable
for installation after wires are terminated to the connector contacts.
3. Insert cable into backshell (1) and bottom against connector. Hold cable in position and
mark cable jacket at rear end of backshell.
4. Remove backshell from connector and place on cable with components from step two above
5. Trim cable jacket at a point 3/4 inch toward connector from mark made in step two above,
exposing cable shielding.
6. Prepare and terminate wires in accordance with established practices.
7. Assemble backshell (1) to connector and tighten securely using appropriate tools.
8. Flare EMI shield completely over grounding ring. Manipulate shield into the connical
counter-bore in the adapter and capture in place with the ground ring.
9. Tighten adapter in place using TG70 strap wrench.
10. Slide O-ring and washer (if provided) against adapter (3).
11. Thread strain relief clamp (5) rmly in place.
12. Tighten saddle bar clamps until they bottom against saddle clamp ears (see saddle clamp
assembly procedure).
Series 390 (Single Shield) EMI/RFI
Environmental Backshell
Assembly Instructions