Thank you for purchasing the Sequence Creation Software SD025-PMX
Wavy for PMX.
SD025-PMX Wavy for PMX is a software application that enables you
to create and execute the sequences on Kikusui PMX Series regulated
DC power supplies via the connected PC.
You can create and edit sequences easily by using a mouse.
During sequence execution, the software indicates the point being
executed.
You can monitor the voltage and current, and save the monitored
data to a file.
The software displays the monitored data as a real-time monitor graph.
This setup guide is included in the Wavy for PMX package. For details
on operation, see the attached operation guide provided in both help and
PDF format. Acrobat reader 9 or later is required to view the operation
guide in PDF format.
Applicable version
This guide applies to version 6.x of SD025-PMX Wavy for PMX. To find
out the version of the Wavy for PMX, click on the [Help] menu and select
[About Wavy].
Related equipment versions
Wavy for PMX applies to PMX series with the following firmware versions.
IOC Ver. 1.10 and later
IFC Ver. 1.10 and later
The firmware version is displayed when you turn on the power switch
of the PMX series.
Related manuals
For details about the PMX series regulated DC power supply, see the
PMX series user's manual.
Trademarks
Microsoft and Windows are either registered trademarks or trademarks
of Microsoft Corporation in the United States and/or other countries.
All company names and product names used in this manual are gener-
ally trademarks or registered trademarks of their rfespective companies.
Copyrights
The contents of this guide may not be reproduced, in whole or in part,
without the prior consent of the copyright holder. The specifications of
this product and the contents of this guide are subject to change without
prior notice.
© Copyright 2015 KIKUSUI Electronics Corporation
SAFETY PRECAUTIONS
Before using Wavy for PMX, carefully read the operation guide of PMX series regulated DC power supply. Be sure to connect and handle the device
properly. Improper connections or handling may lead to serious accidents, injury, and fire.
PART NO. Z1-006-410, IB029231
Feb. 2015
Sequence Creation Software Setup Guide
SD025-PMX Wavy for PMX
Ver 6.x
KIKUSUI ELECTRONICS CORP.
http://www.kikusui.co.jp/en
1-1-3 Higashiyamata, Tsuzuki-ku, Yokohama, 224-0023, Japan
Tel: +81-45-593-7570 Fax: +81-45-593-7571
Website
INSTALLATION
An administrator account is required for the following installation.
Installing the VISA library
To use the PMX series, VISA library needs to be installed on your PC.
VISA (Virtual Instrument Software Architecture) library is a standard
specification for measurement instrument connection software, which
was developed by VXIplug&play Sytems Alliance. One of the following
VISA libraries is required.
NI-VISA by National Instruments (Ver.4.0 or later)
Keysight VISA by Keysight Technologies (formerly Agilent Technolo-
gies) (Keysight IO Libraries Suite14.2 or later)
KI-VISA Ver 5.1.2 or later
KI-VISA is an original VISA library developed by Kikusui Electronics Cor-
poration, which supports IVI VISA 5.0 specification. You can download
the latest version of this library through our website (http://www.kikusui.
co.jp/download/).
If NI-VISA or Keysight VISA is already installed on your PC, you do not
need to install KI-VISA.
1
Insert the CD-ROM to your CD-ROM drive.
A setup window appears. Otherwise, double-click "AutoRun.
exe" included in the CD-ROM.
2
Click [Install] under [1. The installation of the VISA li-
brary for using the USB or LAN].
Click [Install (x64)] for 64-bit OS or [Install (x86)] for 32-bit OS.
The VISA library installation initiates. In case that a VISA library
has already been installed, the VISA library and its version are
displayed.Do not install multiple VISA libraries on a single PC.
Installing Wavy for PMX
1
Insert the CD-ROM to your CD-ROM drive.
A setup window appears. Otherwise, double-click "AutoRun.
exe" included in the CD-ROM.
2
Click [Install] under [2. The Installation of WAVY].
3
Follow the instructions until the installation is complete.
4
Click [Close].
Uninstalling Wavy for PMX
To remove the [Kikusui SD025-PMX Wavy for PMX], open the [Control
Panel] and click [Program] and [Program and Features].
SYSTEM REQUIREMENTS
Core2 or higher
Windows 8, or Windows 7
2 GB RAM (Minimum)
10 GB or more of free hard-disk space
A display that supports 1024 x 768 or higher resolution (96 DPI)
CD-ROM drive
Mouse
RS232C, USB, or LAN (depending on the interface to use)
If you intend to perform the sequence for a long duration of time, be sure
to install sufficient RAM for better performance. It is recommended to
install RAM larger than 4 GB.
To use a USB interface, ensure that a VISA library is installed on your PC.
In case of using a USB serial converter for RS232C connection, the
software may not function properly.
CONNECTING PC TO PMX SERIES
For details on connecting PC to PMX series, see "Interface Setup" section in the
PMX series Communication Interface Manual. Note that the cables are not included
in the product package.
RS232C The RS232C port on PMX is a D-sub 9-pin connector.
USB To connect PC to PMX series via a USB, use a standard USB cable.
LAN
To connect PC to PMX series via a network hub or router, use a
standard LAN cable (category 5, straight). To connect PC directly to
PMX, use a crossover LAN cable.
Configuring PMX settings
1
Make sure that the PMX output is off.
2
Press [CONFIG] key twice.
The voltmeter displays CF20.
3
Turn [CURRENT] knob to select the interface to use.
Set "232" for RS232C, "uSb" for USB, and "LAn" for LAN.
4
If you selected LAN, press the CONFIG switch, and then turn the
VOLTAGE and CURRENT knobs to set the protocol.
Set DHCP (CF30) and AUTO IP (CF31) to on.
5
Press [LOCAL] key.
The PMX series exits from CONFIG settings.
6
Turn off the PMX series and then back on.
The settings are applied.
To use a fixed IP address for LAN interface, you need to configure the LAN settings
via the web interface. To access the web, search the VXI-11 measurement instru-
ment in the VISA application and then click the hyperlink indicated in the search
result.Once you have configured the settings, set DHCP (CF30) and AUTO IP
(CF31) to "off" and restart the PMX.
STARTING WAVY FOR PMX
Before starting Wavy for PMX, make sure that the power-saving mode and the
screen saver are truned off and all the other applications are closed on your PC.
When your PC supports either Advanced Power Management (APM) or sleep
mode, turn off these functions.
Changing the DPI setting may result in improper appearance of the display.
To start Wavy for PMX,click on the [Start] menu and select [All Programs]. Then,
select [Kikusui], [SD025-PMX], and [Wavy for PMX] in this order.
After launching Wavy for PMX for the first time, you
need to configure the interface.
1
Click on the [Setting] menu and se-
lect [Interface].
2
From [Instrument], select the model
name of the PMX series to connect
to.
RS232C
3
Select [RS232C].
4
Select [COM] port.
USB
3
Select [RS232C].
4
Select the connected PMX from the
[Serial Number].
You can find out the serial number on the
rear panel of the PMX.
LAN
3
Select [Eternet].
4
Select the connected PMX from the
[IP Address].
You can confirm the IP address by refer-
ring to the config settings (CF35 to CF 38)
on the PMX.
If the IP address is not displayed, you
need to search for the device connected
through LAN using the VISA library. For
details, see the operation guide.
5
Click [Test].
Verify that your PC is communicating with
the PMX.
CONFIGURING THE INTERFACE
FEATURE INTRODUCTION
For details on operation, see the attached operation guide in both help and PDF format.
Acrobat reader is required to view the operation guide in PDF format.
Sequence execution
1
Click on [Sequence] menu and select [Mode].
In the [Mode] window, set the operating mode (Constant
Voltage (CV) mode or Constant Current (CC) mode), the ex-
ecution time unit, and the repetition count.
2
Create the steps.
You can create steps by either drawing the lines in [Graph]
window or directly entering values in [Worksheet] window.
You can also configure protection functions.
Save the created steps to a file which you can edit later on.
3
Click on [Sequence] menu and select [Run].
The [Run] window opens and the sequence is executed.
You can have both the setting graph and real-time monitor
graph appear in the [Run] window.
During execution, the repetition count, the step position, and
the elapsed time are displayed.
Depending on the monitoring configuration, voltage and/or
current values are also displayed.
The monitored data can be saved to a file.
Remote control panel
You can use Wavy for PMX to set the PMX series voltage and cur-
rent, turn the output on and off, and monitor values.
Cammand control
You can send PMX series commands from Wavy for PMX.
SPECIFICATIONS
Operating Mode: Constant Voltage (CV), Constant Current (CC)
Number of Significant Decimal Places*1: 3 digits
Monitoring: Output current value, output voltage value
Monitoring Interval*2: 200 ms to 600 000 ms (0.2 s to 600 s)
Total Number of Steps: 1024
Range of Sequence (Interval)
*2
Unit Range Setting resolution
s (seconds) 0.5 s to 999.5 s 0.5 s
min (minutes) 0.1 min to 999.9 min 0.1 min
h (hours) 0.1 h to 999.9 h
0.1 h
*1This depends on the range of the connected PMX Series.