Tel:+86-0755-26517682 Fax:+86-0755-29500756 E-mail:yezhan@yezhan.com.cn http://www.yezhan.com.cn
1000 Cy cles(-55℃ to +125℃)
Measurement at 24±2hours after test conclusion
High Temperature
Exposure
1000hrs.@T=125℃.Unpowered.
Measurement at 24±2hours after test conclusion
1000hrs 85℃/ 85%RH。Note:Specified conditions:10% of
operating power.
Measurement at 24±2hours after test conclusion
Condition D Steady State TA=125℃ at rated power.
Measurement at 24±2hours after test conclusion
5 g's for 20 min, 12 cycles each of 3 orientations.
Note: Use 8"X5" PC B .031" thick 7 secure points on one lo ng
side and 2 secure points at corners of
opposite sides. Parts mounted within 2" from any
secure point. Test from 10-2000 Hz.
Measurement at 24±2hours after test conclusion
Resistance to
Soldering Heat
260℃±5℃,10s±1s
Measurement at 24±2hours after test conclusion
5×Rated power for 5 s
Measurement at 24±2hours after test conclusion
电气性能 Electrical Features
降功率曲线 Power Derating Curve
温 度系数曲线 TCR Derating Curve
备注:功率测试板采用铝基板 Note:Power test boards use aluminum substrate