SPECIAL FEATURES
Tamper-protected, safe kind of blanking a door
by direct connection with a position detector
Longer door life cycles by an intelligent,
material pres erv ing hold mechanism
Full integrati on into the door c ontrol ler , which means
Plain text diagnosis instead of flash codes
Automatic teach in of the clo sed pos itio n
Alignment- and setup assista nce during installation
Numerous adapt ion opt ion s like blanking of beams
outside the detection zone
Easy installation by compact cross section siz e
(12 mm x 22 mm)
High ambient light resistance
TST LGB
Light Curtain for aut om atic doors
TECHNICAL DATA
Bar lengths
(H x W x D) Type A: 2.637 x 12 x 22 mm
Type B: 2.408 x 12 x 22 mm
Type C: 2.087 x 12 x 22 mm
Type D: 1.537 x 12 x 22 mm
Type E: 987 x 12 x 22 mm
Connection
M128 / 4 pol. plug
Supply voltage
24 V
DC
+/-10%
Current consumpti on (Type A)
Transmitter:50 mA, Receiver:25 mA
Cross se ct io n siz e
12 mm x 22 mm
Detection range
up to 10 m
Transmitting light
Infrared (850 nm), Laser class 1
Opening angle
+
Ambient light immunity
100 kLUX
Reaction time
< 9 ms (Danger zone)
< 100 ms (Object zone)
Door closing speed
max. 1,6 m/s;
no restriction on open ing
Resolution
up to 300 mm: 22,9 mm
up to 2.500 mm: 137,5 mm
Temperature range
Operation -25°C up to 60°C
Storage -40°C up to 70°C
Humidity
up to 90% not condensing
P
rotection clas s IP67
STANDARD CONFORMITY
& APPROVALS
2006/42/EG
Machinery directive
2004/108/E
G EMC guideline
2006/95/EG
Low voltage guideline
DIN EN 13849
-1:2008-12 Cat 2/ PL d
DIN EN 12978:2009
-10
DIN CLC/TS 61496
-2:2008-02 BWS Ty pe 2
EN 60335
-1:2012-10
EN 61000
-6-1:2007-10
EN 61000
-6-2:2011-06
EN 61000
-6-3:2012-11
EN 6100
-6-4:2011-09
EN 6052
9:2000-09 IP67
DIN EN 12453:2001
-02 Level of protecti on E
DIN EN 12445:2001
-02
FEIG ELECTRONIC reserves the right to change
specifi cation witho ut noti c e at an y tim e.
State of information ist February 2015.
LENGTH VARIANTS TST LGB