WHITE GOODS FILTERS
www.AstrodyneTDI.com
Specications are subject to change. Consult factory to verify specications.
For more information on our lter products call us at: (800) 527-4362 or (714) 289-0055
LCR, Radius Power, and Filter Concepts are now part of Astrodyne TDI
Specications
Electrical Schematic
Rated Voltage Max. (V) 250 VAC Leakage Current
Rated Current (A) 10-16 A @ 40°C @ 250 VAC 50 Hz 0.89 mA Max.
Operating Frequency (Hz) 50/60 Hz @ 115 VAC 60 Hz 0.49 mA Max.
Hipot Rating IP Class IP53
Line to Line 1450 VDC Climatic Category (EN60068-1) 25/85/21
Line to Ground 2250 VDC Flammability UL 94 V-0
Case Plastic Resin
Packaging Quantity 50 Pcs per Carton
Features
Outstanding dierential mode suppression.
Typical Applications
Top load and front load washing machines.
LCR 095/03/04
High Performance Washing Machine Filters
Model No.
Rated
Current
(A) @ 40°C
CM L (mH) DM L (mH) Cx1 (uF) Cx2 (uF) Cx2 (nF) R (Ω) Schematic
Unit
Weight (g)
Terminal Options
In Out
095.31001.00 10 3.0 18 0.47 1.0 4.7 0.68 M A 200 QD 6.35*0.8 QD 6.35*0.8
095.31201.00 12 3.0 18 0.47 1.0 4.7 0.68 M A 200 QD 6.35*0.9 QD 6.35*0.9
095.31601.00 16 3.0 18 0.47 1.0 4.7 0.68 M A 200 QD 6.35*0.10 QD 6.35*0.10
095.31602.00 16 3.0 18 0.68 1.0 4.7 0.68 M A 200 QD 6.35*0.11 QD 6.35*0.11
095.41001.00 10 12.0 0.47 0.68 4.7 0.68 M B 200 QD 6.35*0.12 QD 6.35*0.12
095.41201.00 12 8.0 0.47 0.68 4.7 0.68 M B 200 QD 6.35*0.13 QD 6.35*0.13
095.41601.00 16 5.0 0.47 0.68 4.7 0.68 M B 200 QD 6.35*0.14 QD 6.35*0.14
095.41602.00 16 12.5 0.47 0.68 4.7 0.68 M B 200 QD 6.35*0.15 QD 6.35*0.15
095/04 Electrical Schematic
B
A
2
21
1
L
G
N
UL
UN
095/03 Electrical Schematic
21
L(2)
N(4)
U(1)
LOAD
LINE
U(3)
GND
095/04 Electrical Schematic
B
A
2
21
1
L
G
N
UL
UN
095/03 Electrical Schematic
21
L(2)
N(4)
U(1)
LOAD
LINE
U(3)
GND
WHITE GOODS FILTERS
www.AstrodyneTDI.com
Specications are subject to change. Consult factory to verify specications.
For more information on our lter products call us at: (800) 527-4362 or (714) 289-0055
LCR, Radius Power, and Filter Concepts are now part of Astrodyne TDI
LCR 095/03/04
High Performance Washing Machine Filters
Insertion Loss (dB)
Insertion Loss (dB
)
Frequency (MHz) Frequency (MHz)
10A
16A
12A
16A
095.31001.00 095.31201.00 095.31601.00 095.31602.00
0
20
40
60
80
100
0.1 1 10 100
0
20
40
60
80
100
0.1 1 10 100
1 inch=25.4 mm (All dimensions in mm)
For reference purpose only
FASTON Terminal
6.35*0.8
M8 Screw
80
48
45
40
10.5
11.8
Φ20
10.5
Φ3.5
4
15
LCR 095/03 Mechanical Outlines
LCR 095/03 Insertion Loss in dB Measured in a 50 Ω System
Common Mode
Dierential Mode