30B
Oiles 300 Bushings (Thin wall)
●
Use Oiles 300 in lubrication oil or with
periodic lubrication.
Motion
direction
Mating shaft Bushing
φd
φD
1.6
( )
h7
Housing
H7
chamfer
6.3
( )
Part No.
Specify Part No. by required I.D., O.D., and Length.
(e.g.) I.D. is 8mm, O.D. is 10mm, and length is 12mm.
30B - 081012 T
L
I.D. O.D.
φ
d
Tolerance
φ
D
Tolerance
5
5
6
8
10
12
12
14
14
16
16
18
20
7
8
10
12
14
16
16
18
18
20
22
24
050705T
060805T
6
050706T
060806T
081006T
8
050708T
060808T
081008T
101208T
121408T
121608T
10
060810T
081010T
101210T
121410T
121610T
141610T
141810T
161810T
T162010
12
081012T
101212T
121412T
121612T
141612T
141812T
15
101215T
121415T
121615T
141615T
141815T
161815T
162015T
20
121420T
121620T
141620T
141820T
161820T
162020T
182220T
202420T
30
182230T
202430T
+0.058
+0.058
+0.062
+0.068
+0.081
+0.081
+0.081
+0.081
+0.081
+0.089
+0.089
+0.105
+0.034
+0.034
+0.034
+0.041
+0.041
+0.041
+0.041
+0.041
+0.041
+0.049
+0.049
+0.049
+0.030
+0.030
+0.034
+0.034
+0.047
+0.047
+0.047
+0.047
+0.047
+0.047
+0.047
+0.063
※
The I.D. tolerance after press fitting is for reference only.
Length
L
Tolerance
0
−
0.2
I.D. tolerance
after press
fitting
(reference)
C0.3
C0.3
C0.3
C0.3
φd
φD
L
+0.019
+0.019
+0.019
+0.023
+0.023
+0.023
+0.023
+0.023
+0.023
+0.028
+0.028
+0.028
+0.012
+0.012
+0.012
+0.012
+0.020
+0.020
+0.020
+0.020
+0.020
+0.020
+0.020
+0.030
+0.040
+0.040
+0.040
+0.046
+0.054
+0.054
+0.054
+0.054
+0.054
+0.062
+0.062
+0.072
The dimensional tolerances are the values measured at +25
℃
.
261
Oiles 300 Bushings
Thin wall
Press-fitting
Housing chamfer
For the housing chamfer, either a round chamfer or a
tapered chamfer is recommended. In case of a
C-surface chamfer, (more than C1.0) make sure there
is no burr. Smoother press-fitting is possible by
applying small amount of grease or lubricant.
Press-fit force
Press-fit smoothly with hydralic (pressure), pneumatic
pressure, or a vice. Avoid press-fit by use of impact
such as use of a hammer. It might induce damage of
the bushing, or change the size of the inner diameter
after press-fit.
Press-fitting jig
Generally, as shown in the figure 1, a mandrel is used
for the press-fitting. However use of a guide ring
facilitates easier press-fitting. Use of a guide ring
prevents damage of a bushing at the time of
press-fitting. The dimension of a guide ring should be
calculated from the table below.
Inner diameter of the guide ring should be the size so
that the bushing can be inserted by hands. Length of
the guide ring should be more than one-third of the
bushing, or if possible, it should be the same length as
the bushing.
Dimension of bushing
I.D. D
0
O.D. D1
Length L
Dimension of mandrel
d
0=D0−(0.05 to 0.10)
d1=D1−(0.20 to 0.30)
R≧L
The dimension of mandrel should be calculated
from table below.
Load Load
Mandrel
Bushing Guide ring
Housing
Regular press-fitting Press-fitting with guide ring
L
R
D0
d0
d1
D1
The dimension of guide ring should be calculated
from table below.
Bushing I.D.
Up to φ20
Guide ring O.D.
D1+(10 to 15)
Guide ring I.D.
D1+(0.1 to 0.3)
Figure 1
Figure 2
D1+(10∼15)
D
1+(0.1∼0.3)
Mandrel
Bushing Guide ring
262