Riedon Inc. 300 Cypress Avenue Alhambra CA 91801 (626) 284-9901 (626) 284-1704
www.riedon.com sales@riedon.com
Revised: 201906_001
© Riedon, Inc.
RTDS Series
Thin Film Platinum Temperature Sensor
Sizes: 0805 / 1206
Standardized nominal values
Wide temperature range from -50° to +150°C
Class 0.1%, 0.15% and 0.3% tolerances
TCR of 3850ppm from 0° to 100 °C
DIN EN 60751 compliant
Halogen Free
SPECIFICATIONS
Type
Resistance
Values
(Ω @ 0°C)
DIN Class | Tolerance
Dimensions
L
inches (mm)
B
inches(mm)
D
inches (mm)
C
inches (mm)
RTDS0805
100, 500, 1K
AA | 0.1% (0° to +150°C)
A | 0.15% (-30° to +150°C)
B | 0.3% (-50° to +150°C)
0.079 ±0.008
(2.00 ± 0.2)
0.051 ±0.008
(1.30 ± 0.2)
0.019 ±0.008
(0.50 ± 0.2)
0.015 ±0.008
(0.40 ± 0.2)
RTDS1206
0.122±0.008
(3.10 ± 0.2)
0.059±0.008
(1.50 ± 0.2)
0.031±0.008
(0.80 ± 0.2)
0.025±0.008
(0.63 ± 0.2)
Ordering Information
Part Description: Part Type - DIN Class- Resistance
Example: RTDS1206AA 500 OHM
Bulk packaging is standard, card tape per EN 60286-3 is available in multiples of 5,000 pieces
Card tape packaging allows for a minimum 12 month storage in normal environmental conditions
Resistance Value
(Ω @ 0°C)
Recommended
Measurement Current
Maximum Current
100 1.0 mAmps 7.0 mAmp
500 0.7 mAmp 3.0 mAmp
1K 0.1 mAmp 1.0 mAmp
Type
Self Heating Coecient Δt = i
2
* R * E Response Time (Seconds)
in Water (v=0.2m/s) in Air (v=2m/s) in Water (v=0.4m/s) in Air (v=1m/s)
RTDS0805
0.02 K/mW 0.15 K/mW 0.1 (t
0.5
) 0.3 (t
0.9
) 2.6 (t
0.5
) 7.9 (t
0.9
)
RTDS1206
0.02 K/mW 0.20 K/mW 0.1 (t
0.5
) 0.3 (t
0.9
) 3.3 (t
0.5
) 9.5 (t
0.9
)
Insulation Resistance >10 MΩ at room temperature
Stability < 500ppm / year
Terminations Electroplated tin wrap-around contacts with diusion barrier
Processing
Solderability per DIN IEC 68 part 2
Reow: ≤ 240°C / 8s
Flood: ≤ 260°C / 10s
Storage MSL-1
Operating Conditions
RTDS series temperature sensors may not be used in unprotected moist environments or
in aggressive atmospheres. User should verify suitablility on a case by case basis.