Installation Instructions
52066425 REV 2 © 2015 Greenlee Textron Inc. 3/15
fiberTOOLS is a trademark of Textron Innovations Inc.
Greenlee Splice-on Connectors
Note: This splice-on connector is compatible with 900 µm optical ber.
Greenlee splice-on connector contains the following items:
A. (1) Handle, each kit contains a limited number
B. (1) Outer housing (SC style only)
C. (1) Splice-on connector (SOC) pigtail with cleave protector and ber alignment sleeve
D. (1) 27 mm mini splice sleeve
E. (1) Universal strain relief boot
F. (1) Fiber positioning tool (not pictured)
Note: If ber alignment sleeve has become separated from the SOC body, do not attempt to
re-install; discard it.
A B C D E
Cable Preparation
Slide the 900 μm strain relief boot and then the 27 mm mini splice protective sleeve over the
900μm eld ber. Use the 910CL to cleave the eld ber. Insert the ber adapter with the cleaved
ber into the left-hand side of the 910FS fusion splicer. Make sure to butt the 900 μm buffer up to
the edge of the ber adapter. This will ensure that the mini splice sleeve will adhere to both sides
of the 900 μm buffer.
Installation
1. Disable the “Proof Test” on the fusion splicer.
2. Remove the factory dust cap from the connector.
Note: The extended dust cap may be placed on at this time, if so desired, to aid in
the transfer of the connector. DO NOT LEAVE THE EXTENDED DUST CAP ON THE
CONNECTOR, INSIDE THE FUSION SPLICE MACHINE.
3. While holding the connector rmly, pull down on the cleave protector to remove it from the
connector (Figure 1).
Note: Do not touch the cleaved ber stub with the protector or your ngers as this may
damage the factory cleave.
Figure 1
4. Insert the connector into the universal splice-on connector holder so that the back end of
the connector is ush with the end of the holder (Figures 2-5). Once aligned properly, the
connector should t freely into the holder with no force required.
Figure 2 (SC) Figure 3 (FC) Figure 4 (LC) Figure 5 (ST)
Installation Instructions
USA Tel: 800-435-0786
Fax: 800-451-2632
Canada Tel: 800-435-0786
Fax: 800-524-2853
4455 Boeing Drive • Rockford, IL 61109-2988 ��� USA • 815-397-7070
An ISO 9001 Company • Greenlee Textron Inc. is a subsidiary of Textron Inc.
International Tel: +1-815-397-7070
Fax: +1-815-397-9247
www.greenlee.com
5. Insert the holder into the right-hand side of the splicer (Figure 6), making sure that the ber
stub lays properly into the V-groove block of the splicer. You may use the ber positioning
tool to help align the ber in the V-groove. The ber for FC and ST splice-on connectors must
have the ber laying in the end of the ber groove in the V-groove. The ber positioning tool
can be used to align the ber with the V-groove. Turning the ber and/or the connector may
also be necessary to accomplish this. The FC/ST ber adapter may also need to be twisted
slightly to ensure that the ber is aligned with the V-groove.
Note: Make sure that
the edge of the 900
micron tight buffer is
even with the edge of
the 900 micron fiber
adapter.
Note: Remove the
extended dust cap
before initiating the
fusion splice.
Figure 6
6. Perform the fusion splice as described in the fusion splicer manufacturer’s instructions.
7. Once the fusion splicing cycle is completed, remove the connector from the splicer and slide
the splice protection sleeve up to cover the splice. Make sure that the splice protector is
positoned against the connector body.
Note: The extended cap may be put in place now to aid in the transfer to the splice sleeve
oven.
8. Transfer the splice to the splice sleeve heat oven on the right-hand side (Figure 7). Verify the
position of the splice sleeve is butted up against the metal portion of the splice-on connector.
Use the 60 mm heater mode #1 with center and edges activated. Press the HEAT button to
run the shrink cycle.
9. Verify that the splice protection sleeve is completely shrunk onto the ber to avoid the end
catching on the strain relief boot. If the splice sleeve is not completely shrunk, then place it
back in the sleeve oven and initiate a second heat cycle.
Note: Make sure that the splice sleeve has fully cooled before sliding the strain relief boot into
place. For SC connectors, install the outer housing onto the connector, being sure to align the
angled corners of the inner housing with those of the outer housing (Figure 8).
Figure 7 Figure 8
Compatibility Chart
The Greenlee SOC adapter allows the Greenlee 900 micron SOC to be used in competitors’ fusion splicers.
Manufacturer AFL Sumitomo Fitel INNO FIS
Model FSM11 (S/M) FSM-17S FSM-18S Type-25e (U/S/M) S122(A/C/M/) IFS10 CA3
FSM-19S Type-39FH S121 (A/M) IFS15
FSM-60(S/R) Type-46 S123 (C/M)
FSM-70(S/R) Type-66 S153
Quantum (Q101-CA) S178A
Compatible fiberTOOLS™ SOCs All versions SC and LC only SC, LC and ST only All versions All versions All versions All versions
Greenlee SOC Adapter 52075260 52075260 52075260 52075282 52075281 52075283 52075284
Visit www.greenleecommunications.com for an updated compatibility list and a video demonstration of the SOC.