2000W Pure Sine Wave Inverter / Charger SC-2000 series
Feature:
Bi-directional All-in-One Design
Certied by UL
5-in-1 Operating Modes
Compact Size
Inverter Mode
Charger Mode
Environment
SC-2000-112 SC-2000-124 SC-2000-212 SC-2000-224
UL458 & Supplement SA / CSA C22.2 No. 107.1-01
UL1741 / CSA C22.2 No. 107.1-01 / KKK-A-1822F (For Ambulance)
1. Inverter mode 2. Charger mode 3. Power Sharing 4. Power Generation
5. Power Support
Highly Integration = Installation hassle-free
Nominal Voltage
Input Voltage Range
(±0.5V)
Input Over-Voltage Protection (±0.5V)
Input Over-Voltage Warning (±0.5V)
Input Under-Voltage Protection (±0.5V)
Input Under-Voltage Warning (±0.5V)
Input Current (Max)
No Load Current
Stand-By Current
Continuous Output Power
Surge Power
Frequency
Output Voltage
Max. Eciency (Full Load)
Output Waveform
INV. AC Output*
AC Output*
Input Protection
AC Output Protection
AC Input Protection
Temperature protection
Battery Temperature protection
Input
Output
Protection
12 VDC
10.5 ~ 16.5 VDC
16.5 VDC
15.5 VDC
10.5 VDC
11.0 VDC
260 A
< 4.0 A @12.5V
< 0.4 A
2000 VA ± 3%
Load 101%~115% (1 Min) / 4000 VA (2 Sec)
50/60 Hz ± 0.3 Hz (User-selectable)
100 / 110 / 115 / 120VAC ±3%
89%
Pure Sine Wave (THD < 5% @ 12.5V/25V/115VAC, linear load) / (THD < 3% @ 12.5V/25V/230VAC, linear load)
20A MAX
30A MAX
Over / Under Voltage, Reverse Polarity (Internal Fuse)
Short-Circuit, Overload
30 Amp Circuit Breaker
Shutdown
By a RJ-11 connector to battery Temperature sensor
24 VDC
21.0 ~ 33.0 VDC
33.0 VDC
31.0 VDC
21.0 VDC
22.0 VDC
130 A
< 2.0 A @25V
< 0.2 A
90%
212 VDC
10.5 ~ 16.5 VDC
16.5 VDC
15.5 VDC
10.5 VDC
11.0 VDC
260 A
< 4.0 A @12.5V
< 0.4 A
200 / 220 / 230 / 240VAC ±3%
89%
10A MAX
26A MAX
16 Amp Circuit Breaker
24 VDC
21.0 ~ 33.0 VDC
33.0 VDC
31.0 VDC
21.0 VDC
22.0 VDC
130 A
< 2.0 A @25V
< 0.2 A
90%
Nominal Voltage / Frequency
Input Voltage Range
Input Frequency Range
Nominal Current
Eciency (Max.)
AC Input*
Power Factor Correction (PFC)
Output Voltage
Output Current
Charging Current Range
Max. Output Voltage
Battery Temperature Compensation
Battery Control
(3-stage Battery Chargers)
Remote Control Panel (Optional)
Remote Control Terminal
Dry Contact Terminal
Relay Specication
AC input
Auxiliary DC Output
DC Output
Signal and Control
110 VAC, 50 / 60Hz (User-selectable)
90 ~ 132 VAC
50Hz:47 ~ 53 Hz / 60Hz:57 ~ 63 Hz
16.5A (@110VAC)
>88%
30 A MAX
>0.95 (Max.)
Battery Voltage
20A Max
25 / 50 / 75 / 100A
14.4 VDC@ GEL TYPE
-25 mV per
Bulk / Absorption / Float
CR-20C / CR-16B / CR-8
Controls the inverter ON / OFF operation
By a relay
30 Amp / 120 VAC @ 110V system
Full Load
Power de-rating
Storage
Operating Temperature
Range
Operating Humidity
Range
Cooling
-20 ~ 40
60 W / , 41~60
-30 ~70
Max 93%, Non-condensing
Temperature & Load Controlled Cooling Fan
12.5 / 25 / 37.5 / 50A
28.8 VDC @ GEL TYPE
-50 mV per
230 VAC, 50 / 60Hz (User-selectable)
180 ~ 264 VAC
7.9A (@230VAC)
16 A MAX
25 / 50 / 75 / 100A
14.4 VDC @ GEL TYPE
-25 mV per
16 Amp / 250 VAC @ 230V system
12.5 / 25 / 37.5 / 50A
28.8 VDC @ GEL TYPE
-50 mV per
The Battery Charger
Safety and EMS
Other
SC-2000-112 SC-2000-124 SC-2000-212 SC-2000-224
2000W Pure Sine Wave Inverter / Charger SC-2000 series
BULK ABSORPTION FINAL
BATTERY VOLTAGE
CURRENT (I)
T
Imax
<Imax
Start max builk timer: 13.50 VDC
13.50VDC
14.40VDC
Reurn to bulk : 12.80VDC
BULK
ABSORPTION FLOAT
BULK
repeated
every 336 hr
85
mm
30
sec
return to
bulk timer
Bulk
Float
lmax 100%
Return amps= 6% lmax
= voltage
= current
12.80VDC
Charge characteristic of the three-step Plus charging method
min. bulk timer : 2 min
Absorption
14.25VDC
max. bulk
timer : user
select
8 ~ 18 hr
max. absorption
timer: 4 hr
min. abs timer : 15 min
Three step charge system
Charge characteristic of three-step plus charging method
Safety Standards
E-mark
EMC Standards
Dimension (W x H x D)
Net Weight
UL458 & Supplement SA / UL1741
---
Certied FCC Class A*
251 x 116 x 453mm
6 Kg
EN 62368-1
Certied CISPR 25; ISO7637-2
EN55032 Class A*, EN55024 Class A*
EN61000-3-2, 3-3 , EN61000-4-2, 3, 4, 5, 6, 8, 11
*Max Inverter output dene inverter 100% load output at Vac =100V / 200V
*Max AC output dene AC input current + Inverter output current, cannot over AC input limit.
*Max AC input current Limit by the Breaker
*SC series is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.