Only One Name Means ProTek’Tion™
05113.R41 10/18 Page 1
05113
30KPA Series
30kW POWER TVS COMPONENT
ISO 9001: 2015 CERTIFIED
DESCRIPTION
The 30KPA Series, are discrete 30,000 Wa, silicon transient voltage suppressors (TVS) designed for use in applicaons
where large voltage transients can permanently damage voltage sensive components and equipment.
The 30KPA series is available in voltages ranging from 30V to 360V with 5 percent and 10 percent tolerances. Both
tolerances are referenced to the power supply output or operang voltage level. This series is compable with IEC
61000-4-5 (Surge) requirements.
FEATURES
RTCA DO-160G COMPLIANT PRODUCT
UL File Recognion #E208219
Compable with IEC 61000-4-5 (Surge): 48A, 8/20µs - L3(Line-
Ground), L4(Line-Line) & L1 (Power)
30,000 Was Peak Pulse Power per Line (tp = 10/1000µs)
Unidireconal and Bidireconal Conguraons
Easy Mounng to Printed Circuit Board
tClamping (0V to V
BR
Min.) < 1 x 10
-12
seconds theorecal
Available in Mulple Voltage
RoHS Complaint (Exempon #7)
MECHANICAL CHARACTERISTICS
Molded Case
Approximate Weight: 5 grams
Lead-Free Pure-Tin Plang (Annealed)
Solder Reow Temperature:
Pure-Tin - Sn, 100: 260-270°C
Flammability Rang UL 94V-0
APPLICATIONS
Relay Drives
Motor (Start/Stop) Back EMF Protecon
Module Lightning Protecon
Secondary Lightning Protecon for AC/DC
CIRCUIT DIAGRAMS
AXIAL LEAD PACKAGE
UNIDIRECTIONAL BIDIRECTIONAL

Only One Name Means ProTek’Tion™
05113.R41 10/18 Page 2
05113
30KPA Series
30kW POWER TVS COMPONENT
ISO 9001: 2015 CERTIFIED
MAXIMUM RATINGS 
PARAMETER SYMBOL VALUE UNITS
Peak Pulse Power (tp = 10/1000µs) - See Figure 1 P
PP
30,000 Was
Forward Surge Rang - 1/120 seconds - See Note 2 I
F
200 Amps
Steady State Power Dissipaon P
P
8.0 Was
Storage Temperature T
STG
-55 to 150 °C
Operang Temperature T
L
-55 to 150 °C
Typical Thermal Resistance, Juncon to Lead R
ΘJL
8.0 °C/W
Typical Thermal Resistance, Juncon to Ambient R
ΘJA
40 °C/W
ELECTRICAL CHARACTERISTICS PER LINE 
PART
NUMBER
Notes 
RATED

VOLTAGE
V
WM
VOLTS
BREAKDOWN
VOLTAGE
MAXIMUM
LEAKAGE
CURRENT

WM
I
D
µA
MAXIMUM
CLAMPING
VOLTAGE
(Fig. 2)
µS
V
C

PP
TEMPERATURE
COEFFICIENT
OF V

qV

m
MIN
V

VOLTS

T
mA
30KPA28A 28.0 31.28 50 5000 50.0V @ 606.0A 32
30KPA30A 30.0 33.3 50 5000 55.2V @ 543.0A 34
30KPA33A 33.0 36.7 50 5000 58.6V @ 512.0A 39
30KPA36A 36.0 40.0 50 2000 61.8V @ 485.0A 41
30KPA43A 43.0 47.8 50 1000 73.0V @ 410.0A 50
30KPA45A 45.0 50.3 5 250 77.4V @ 391.5A 51
30KPA48A 48.0 53.3 5 250 77.4V @ 388.0A 56
30KPA51A 51.0 57.00 5 50 86.4V @ 350.7A 60
30KPA54A 54.0 60.0 5 20 91.4V @ 331.5A 64
30KPA58A 58.0 64.4 5 20 92.4V @ 325.0A 68
30KPA64A 64.0 71.1 5 10 104.0V @ 294.0A 76
30KPA70A 70.0 77.8 5 2 109.0V @ 274.0A 83
30KPA72A 72.0 80.4 5 2 114.0V @ 265.0A 85
30KPA75A 75.0 83.3 5 2 119.4V @ 251.0A 89
30KPA78A 78.0 87.10 5 2 129.0V @ 234.9A 92
30KPA85A 85.0 94.4 5 2 139.0V @ 216.0A 105
30KPA90A 90.0 100.0 5 2 147.0V @ 206.0A 109
30KPA100 100.0 111.0 5 2 179.0V @ 168.0A 134
30KPA100A 100.0 111.0 5 2 162.0V @ 186.0A 121
30KPA102A 102.0 114.0 5 2 166.0V @ 183.0A 124
30KPA110A 110.0 122.0 5 2 178.0V @ 168.0A 126
30KPA130A 130.0 144.0 5 2 209.0V @ 142.0A 157
30KPA150A 150.0 167.6 5 2 233.4V @ 129.8A 195
