LED C.V. Power Supply 75W Dimmable Series
PS_LDP-075-Dim-Series_AR6PT_v2a Page 2
Output Spec. Condition Description Min. Normal Max. Units
Current Accuracy
±5 %
Ripple Current
At 100%-60% Load. The result differs according to different LED
load characteristic.
5 % Ip-p (Io)
Overshoot/Undershoot % of Iout max & LED load 10 %
Turn-On Delay
Measured at 110 VAC/220 VAC input and Full Load 1.2 S
Auxiliary Power (Vaux) With 300mA max -5% 12 +5% Vdc
General Spec. Condition Description Min. Normal Max. Units
Efficiency
Measured at full load and 220Vac in the thermal balanced condition. 90 92 %
MTBF
measured at Tc= 75℃ (MIL-HDBK-217F)
≥320,000 Hours
Lifetime
measured at Tc= 75℃
≥100,000 Hours
Operating/Storage
Temperature
10%RH/5%RH~100%RH (See De-rating Curve for more details)
-40/-40 70/85 °C
Dimension
(OL/L x W x H)
OL is the overall length with mounting plates
158/131 x 67.5 x 33.5 mm
6.22/5.16 x 2.66 x 1.32 inch
Weight
Net weight without package 1.43/0.65 lb/kg
Safety & EMC Compliance Category Condition Description
Safety Regulations
UL8750
Light Emitting Diode(LED) Equipment for Use in Lighting Products
UL1012
Power Unit Other Than Class 2
IEC 61347-1
Lamp Controlgear Part 1: General and Safety Requirements
IEC 61347-2-13
Lamp Controlgear Part 2-13: Particular Requirement for d.c. or a.c. Supplied Electronic Controlgear foe LED Modules
CE Europe: EN 61347-1, EN61347-2-13
EMI Standards
IEC 55015 Conducted emission test & Radiated emission test
IEC 61000-3-2 Harmonic current emissions; Class C (≥75% load)
IEC 61000-3-3
Voltage fluctuations & flicker
FCC Part 15
Class B
EMS Standards
IEC 61000-4-2 Electrostatic discharge (ESD)
IEC 61000-4-3 Radio frequency electromagnetic field susceptibility test (RS)
IEC 61000-4-4 Electrical fast transient (EFT)
IEC 61000-4-5 Surge immunity test
IEC 61000-4-6 Conducted radio frequency disturbances test (CS)
IEC 61000-4-8 Power frequency magnetic field test
IEC 61000-4-11 Voltage dips
IEC 61547 Electromagnetic immunity requirements applies to lighting equipment