2 of 5
www.ConTech-us.com Email: sales@ConTech-us.com Ph: 925-609-1193 / Toll free 877-302-4411 2401 Stanwell Drive, Concord Ca. 94520
eco # 151119-1 18:151015
Input Parameters Min Typ Max Units
Input Surge Voltage (1 sec max.)
24 Vin
48 Vin
-0.7
-0.7
50
100
VDC
Start Voltage
24 Vin
48 Vin
9
18
VDC
Start Up Time 30 mS
Switching Frequency 330 kHz
Input Filter LC Filter
Output Parameters
Min Typ Max Units
Output Voltage Accuracy
±1.0 %
Output Voltage Balance
Dual Output, Balanced Loads
±2.0 %
Load Regulation
Min. Load to Full Load
Single 3.3V & 5V
12V, 15V & 24V
Dual ±12V & ±15V
±0.5
±0.2
±1.0
%
Line Regulation Single Output
Vin=Min. to Max. Dual Output
±0.2
±0.5
%
Ripple & Noise (20MHz)
3.3V & 5V Output Models
12V & 15V Output Models
24V Output Models
±12V, ±15V Output Models
75
100
150
100
mV P-P
Over Current Protection
150 % of Iout
Transient Recovery Time
25% Load Step Change
300 µs
Temperature Coefcient
±0.02 % / ºC
Short Circuit Protection
Hiccup Automatic Recovery
Remote On Off
Min Typ Max Units
DC/DC On
3.5V-12V or Open Circuit
DC/DC Off
0v -1.2V or Short Circuit
Control Input Current (on)
Vctrl = 5.0V
0.5 mA
Control Input Current (off)
Vctrl = 0V
-0.5 mA
Control Common
Referenced to Negative Input
Standby Input Current
Supply Off & Nominal Vin
10 mA
Output Voltage Trim
Min Typ Max Units
Trim Up / Trim Down (7)
% of nominal output voltage
±10 %
See Model Selection Table for Model Specic Parameters
Notes:
1. Specications typical at Ta=+25ºC, resistive load, nominal input voltage,
full rated output current unless otherwise noted.
2. Ripple & Noise measurement bandwidth is 20MHz, measured with a
1µF MLCC and a 10µF Tantalum Capacitor.
3. Transient recovery time is measured to within 1% error band for a step
change in output load 75% to 100%.
4. Water washability - ConTech DC/DC converters are designed to
withstand most solder/wash processes. Careful attention should be
used when assessing the applicability in your specic manufacturing
process. Converters are not hermetically sealed.
5. See ConTech website for Denition of Terms, Application Notes, and
Test Setups and Parameters. www.ConTech-us.com/appnotes.html.
6. Specications subject to change without notice.
7. Output voltage trimming must use resistive components only. Applying
external voltages to the trim pin can cause damage.
8. See ConTech website www.ConTech-us.com/pdf/rohs.pdf for RoHS
Statement.
General Specications
Min Typ Max Units
Isolation Voltage,
60 seconds
1500 VDC
Isolation Resistance
500VDC
1000 Mohms
Isolation Capacitance,
100kHz, 1V
1500 pF
Operating Temperature (Ambient)
-40 +85 ºC
Operating Temperature (Case)
-40 +105 ºC
Thermal Impedance
Natural Convection without heatsink
Natural Convection with heatsink
18.2
15.3
ºC/W
Storage Temperature
-50 +125 ºC
Humidity
95 %
MTBF MIL-HDBK-217F @25ºC,
Ground Benign
451 K Hours
Cooling
Free-Air Convection
Case Size 1.0 x 1.0x 0.4 inches
25.4 x 25.4 x 10.16 mm
Case Material Six-Sided shielded, Metal Case
(UL-94V-0)
Weight
15g
Agency Approvals
CSA 60950-1 Approved