CXup series (10 – 40 A)
www.phocos.com
Advanced PWM Charge Controller with LCD and Datalogging
Product Introduction
The CXup series is a powerful family of PWM charge controllers with advanced
features for 12/24V systems. Featuring a user-friendly, back-lit LCD display, USB
charging port and up to 2-years of system performance data, CXup is ideal for a wide
range of off-grid applications requiring intelligent features.
CXup units are equipped with four, robust touch-sense buttons which allow the user
to scroll through real-time data and make settings changes with ease. The built-in
USB charging port supplies power for charging mobile devices off the main system
battery. All CXup units have an optional dusk-to-dawn load timer which can be
utilized for solar lighting applications.
User friendly LCD display shows extensive system information
Four-stage PWM charging algorithm with integrated
temperature compensation
Full electronic protection
Programmable nightlight function
USB charging port
Data logger information can also be exported
Load status indication
Touch keys ensure long lasting operation
Technical Drawing
Product Features
Charge Controller
Type CXup 10 CXup 20 CXup 40
System voltage 12/24 V auto recognition
Max. charge/load current 10 A 20 A 40 A
Float charge (lead acid battery) 13.8/27.6 V (25 °C)
Main charge (lead acid battery) 14.4/28.8 V (25 °C), 30 min. (daily)
Boost charge (lead acid battery) 14.4/28.8 V (25 °C), 2 h
Activation: battery voltage < 12.3/24.6 V
Equalization charge (lead acid
battery)
14.8/29.6 V (25 °C), 2 h
Activation: battery voltage < 12.1/24.2 V
Charge voltage for LiFePO4
battery
14.0/28.0 V (temperature limit: -20 to +60 °C)
Deep discharge protection:
Cut-o voltage
Lead acid battery: 11.5-12.0 V / 23.0-24.0 V by SOC;
11.0 -11.5 V / 22.0 - 23.0 V by voltage
LiFePO4 battery: 11.5/23.0 V by voltage
Reconnect level 12.8/25.6 V for lead acid battery; 12.2/24.4 V for
LiFePO4 battery
Overvoltage protection 15.5/31.0 V
Undervoltage protection 10.5/21.0 V
Max. panel voltage
(Surge protection by varistor)
30 V in 12 V system
50 V in 24 V system
Temperature compensation
(Charge voltage)
−25 mV*K at 12 V
−50 mV*K at 24 V
Idle self-consumption < 4 mA
Grounding Positive grounded
Ambient temperature ��40 to +60 °C
Max. altitude 4,000 m above sea level
Battery type Lead acid (GEL, AGM, ooded), LiFePO4
Data logger 2 years
USB charging port 5.0 V; 1,500 mA
External temperature sensor Yes
Wire cross section Up to 16 mm2
Dimensions (W x H x D) 101 x 103 x 32 mm
Weight 168 g 179 g
Type of protection IP20