PIA4800 series List of Message
Applicability:
OP01-PIA1/OP01-PIA+SH SERIES2/OP02-PIA3
PAM (4) /PAS (5) /PMR (6) /PWR (7)
: Available, No mark: Not available
R/W: Query messageR/ Command messageW
1234567
*CLS
- Reset registers.

W
*IDN
- Return the Model Name of the controller.

R
*RST
- Set or reset the fault unmask register.

W
*SRE
0 to 255
Set or reset the service request enable register.
(
E
q
uivalent
to
UNMASK
)

R/W
*STB
- Return the contents of the status byte register.

R
CH
1 to 4 Specify a channel.

R/W
CLR
-
Clear the input buffer.
(
E
q
uivalent
to
DCL
and
SDC
)

W
DELIMITER
0 to 3
Specify a response message terminator.
(
E
q
uivalent
to
TRM
)

R/W
DIN
- Return the port value of the digital control input.

R
DISP
1 to 4 Specify the output which displays on the panel.
W
DSET
0 to 127 Set the value output to the digital control output port.

W
ERR
- Return the contents of the error register.

R
FAU
- Return the contents of the fault register.

R
FUNMASK
0 to 255 Set or reset the fault unmask register.

R/W
HEAD
0 or 1 Specify a header and a unit.

R/W
IOUT
- Return the monitored value of the output current.
*1 *1 
R
ISET
Depends
on
device.
Set an output current.
*1 *1 *1

R/W*2
LOCK
0 or 1 Set to valid or invalid of the panel operation.

W
NODE
1 to 36 Specify the node address.

R/W
OCSET
Depends
on
device.
Set OCP for a currently effective device.

R/W
OUT
0 or 1
Turn ON/OFF the output of a currently effective
device.
*3 *3 *3

W
OVSET
Depends
on
device.
Set OVP for a currently effective device.

R/W*4
POUT
- Return the monitored value of the output power.
R
POW
- Cut off power to a currently effective device.

W
REM
0 or 1 Set REMOTE/LOCAL for a currently effective device.
*5 *5
W
SILENT
0 or 1
Switch acknowledgement messages when using
RS-232C.

R/W
STS
- Return the contents of the status register.

R
TRM
-
Specify a response message terminator.
(
E
q
uivalent
to
DELIMITER
)

R/W
UNMASK
0 to 255
Set or reset the service request enable register.
(
E
q
uivalent
to
*SRE
)

R/W
VOUT
- Return a set value of the output voltage.
*1 *1 
R
VSET
Depends
on
device.
Set the output voltage.

R/W*2
*2: The Query is invalid for the DC power supply with analog remote control function, the PMR series or the PAM series.
*3: Excluding the PLZ-W2 series, the PLZ152WA, the PVS series or thePVD-T series.
*4: The Query is invalid for the DC power supply with analog remote control function.
*5: Only the PAK-A series.
The 1 through 3 as indicated follows are used in combination with the DC power supply with analog
remote
control
function
and
the
control
board.
*1: Excluding the PLZ series.
R/WMessage Data
Description
Applicability