Single Output model
PMX18-2A PMX18-5A
PMX35-1A PMX35-3A
PMX70-1A PMX110-0.6A
PMX250-0.25A
PMX350-0.2A
PMX500-0.1A
Multiple Output model
PMX32-3DU
PMX32-3TR
PMX32-2QU
Communication Interface Manual
Regurated DC Power Supply PMX Series
PART NO. IA005361
Jul. 2018
Communication Interface Manual Regurated DC Power Supply PMX Series
KIKUSUI ELECTRONICS CORP.
http://www.kikusui.co.jp/en
1-1-3 Higashiyamata, Tsuzuki-ku, Yokohama,
224-0023, Japan
Tel: +81-45-482-6353 Fax: +81-45-482-6261
Website
Command List
KIKUSUI Electronics Corp. PMX Interface Manual
*CLS
Clears all event registers including the status byte, event status, and error queue.
*ESE
Sets the event status enable register that is counted by the event summary bit (ESB) of the
status byte.
*ESR
Queries the event status register.
*IDN
Queries the model name, serial number, and rmware version of the PMX.
*OPC
Sets the OPC bit (bit 0) of the event status register when all the commands in standby have
been completed.
*OPT
Queries the option that are installed in the PMX.
*PSC (Multiple-output model only)
Sets whether to clear the event status enable register and the service request enable
register when the POWER switch is turned on (power-on status).
*RCL (Single-output model only)
Recalls settings from the preset memory (A, B, C).
*RST
Resets the panel settings.
*SAV (Single-output model only)
Saves the present voltage, current, OVP, and OCP values in the preset memory.
*SRE
Sets the service request enable register.
*STB
Queries the contents of the status byte register and the MSS (master summary status)
message.
Command List
*TRG (Single-output model only)
Trigger command.
*TST
Executes a self-test.
*WAI
Prevents the PMX from executing subsequent commands until all operations in standby are
complete.
ABOR (Single-output model only)
Aborts the setting change trigger function.
ABOR:DTF (Multiple-output model only)
Aborts the parallel or series operation of channels 1 and 2.
FETC:ALL (Multiple-output model only)
Queries the measured value of the current and voltage.
FETC:CURR (Multiple-output model only)
Queries the measured value of the current output.
FETC:VOLT (Multiple-output model only)
Queries the measured value of the voltage output.
INIT:TRAN (Single-output model only)
Starts the setting change (TRANsient) trigger function.
INIT:DTF:PARA (Multiple-output model only)
Starts the parallel operation of channels 1 and 2.
INIT:DTF:SER (Multiple-output model only)
Starts the series operation of channels 1 and 2.
INST/ CHAN
Species the channel to congure.
INST:CAT/ CHAN:CAT
Queries the list of channels that can be congured with the INST command.
INST:INFO/ CHAN:INFO
Queries the information of the channel currently being controlled.
INST:UNS/ CHAN:UNS (Multiple-output model only)
Releases the designation of the channel under control.