Drawings
All Rights Reserved, Copyright © 2000, Yokogawa Electric Corporation
Subject to change without notice. Printed in Japan.
DY200
Reduced Bore Type (/R1)
Digital Vortex Flowmeter
(Integral/Remote and Flange type)
P -
SD 01F06A00-11EN
SD 01F06A00-11EN
1st Edition: Feb. 1, 2006(YK)
6th Edition: Jan. 31, 2014(KP)
Unit : mm
(approx. inch)
87.5 (3.44)
103.5 (4.07)
H
H1
125 (4.29)
T
L
øD
59 (2.32)
74 (2.91)
59 (2.32)
4.5
(0.18)
ø94 (3.70)
øJ
øCS
øC
N- øG
WITH INDICATOR
ELECTRICAL
CONNECTION
EARTH TERMINAL
TYPE INTEGRAL/REMOTE
MODEL CODE
DY200/R1
PROCESS
CONNECTION
BJ1 BJ2
BA1
BS1
BA2
BS2
L 310 (12.20)
C 185.6 (7.31)
CS 138.8 (5.46)
D 330 (12.99) 350 (13.78) 342.9 (13.50) 381 (15.00)
H
Shedder Bar Material: L, E, X
477.5 (18.80) 487.5 (19.19) 484 (19.06) 503 (19.80)
Shedder Bar Material: B 484.5 (19.07) 494.5 (19.47) 491 (19.33) 510 (20.08)
H1
Shedder Bar Material: L, E, X
209 (8.23)
Shedder Bar Material: B 216 (8.50)
T 22 (0.87) 30 (1.18) 28.4 (1.12) 41.1 (1.62)
J 290 (11.42) 305 (12.01) 298.5 (11.75) 330.2 (13.00)
N 12 12 8 12
G 23 (0.91) 25 (0.98) 22.4 (0.88) 25.4 (1.00)
WEIGHT kg (lb) 58.7 (129.4) 74.1 (163.4) 70.7 (155.9) 102.9 (226.9)
(Note 1) Integral weight is the same as Remote.
(Note 2) In case of with Indicator, add 0.2kg.
(Note 3) The ow direction is opposite (right to left when facing onto indicator) in case of code/CRC.
Integral type Remote type
Terminal Wiring
Integral Type
(BRAIN or HART protocol)
SUPPLY + Power Supply and
4 to 20mA DC Output Terminals
PULSE + Pulse Output Terminals
Integral Type
(Foundation Fieldbus)
SUPPLY +
Fieldbus Communication
Terminals
SUPPLY
Remote Type Detector
T Built-in Temperature Sensor Terminal
A
Signal Output Terminals
B
C Common Terminal
Grounding Terminal
* Use DYC signal cable for remote type.
* T is used for /MV only.