Drawings
All Rights Reserved, Copyright © 2000, Yokogawa Electric Corporation
Subject to change without notice. Printed in Japan.
DY200
Reduced Bore Type (/R1)
Stainless Steel Housing (/E1)
Digital Vortex Flowmeter (Remote and Flange type)
P -
SD 01F06A00-21EN
SD 01F06A00-21EN
1st Edition: Feb. 1, 2006(YK)
4th Edition: Jan. 31, 2014(KP)
Unit : mm
(approx. inch)
TYPE REMOTE
MODEL CODE
DY200/R1/E1
PROCESS
CONNECTION BJ1 BJ2
BA1
BS1
BA2
BS2
L 310 (12.20)
C 185.6 (7.31)
CS 138.8 (5.46)
D 330 (12.99) 350 (13.78) 342.9 (13.50) 381 (15.00)
H
Shedder Bar Material: L, E, X
465 (18.31) 475 (18.70) 471.5 (18.56) 490.5 (19.31)
Shedder Bar Material: B 472 (18.58) 482 (18.98) 478.5 (18.84) 497.5 (19.59)
H1
Shedder Bar Material: L, E, X
209 (8.23)
Shedder Bar Material: B 216 (8.50)
T 22 (0.87) 30 (1.18) 28.4 (1.12) 41.1 (1.62)
J 290 (11.42) 305 (12.01) 298.5 (11.75) 330.2 (13.00)
N 12 12 8 12
G 23 (0.91) 25 (0.98) 22.4 (0.88) 25.4 (1.00)
WEIGHT kg (lb) 58.8 (129.6) 74.2 (163.6) 70.8 (156.1) 103 (227.1)
(Note 1) The ow direction is opposite (right to left when facing onto indicator) in case of code/CRC.
ELECTRICAL CONNECTION
EARTH TERMINAL
øD
L
75.5 (2.97)
91 (3.58)
H1
H
20 (0.78)
5
(0.19)
32.5
(1.28)
N - øG
øC
14.5 (0.57)
øJ
ø78 (3.07)
T
58 (2.28)
øCS
Terminal Wiring
Remote Type Detector
T Built-in Temperature Sensor Terminal
A
Signal Output Terminals
B
C Common Terminal
Grounding Terminal
* Use DYC signal cable for remote type.
* T is used for /MV only.
Remote type detector (DY-N
...
/E1)
DYC
T
A
B
C