25, Wu Chyuan 7th Road, New Taipei Industrial Park, Wu Ku District, New Taipei City, Taiwan /新北市五股區新北產業園區五權七路25
t+886 (02)2299 3939 f+886 (02)2299 3237 www.sgs.tw
Member of the SGS Group
SGS Taiwan Ltd. 台灣檢驗科技股份有限公司
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx
and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Termse-Document.aspx. Attention is
drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s
findings at the time of its intervention only and within the limits of client’s instruction, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties
to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced, except in full, without prior written approval of the
Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested.
Page : 1 of 7
:
:
:
:
:
============================================================================================
:
:
:
Test Report
No. : CE/2017/83612 Date : 2017/08/23
MINMAX TECHNOLOGY CO., LTD.
DC-DC CONVERTER
MSLU1XX SERIES
*CE/2017/83612*
MINMAX TECHNOLOGY CO., LTD.
NO. 18, SIN-SIN ROAD, AN-PING INDUSTRIAL DISTRICT, TAINAN 702, TAIWAN
Sample Submitted By
The following sample(s) was/were submitted and identified by/on behalf of the applicant as :
Test Requested
As specified by client, to test Cadmium, Lead, Mercury, Cr(VI), PBBs, PBDEs, DBP,
BBP, DEHP, DIBP contents in the submitted sample(s).
Please refer to following pages.
Please refer to following pages.Test Method
2017/08/16
Test Result(s)
Testing Period
Sample Receiving Date
Sample Description
Style/Item No.
2017/08/16 TO 2017/08/23
25, Wu Chyuan 7th Road, New Taipei Industrial Park, Wu Ku District, New Taipei City, Taiwan /新北市五股區新北產業園區五權七路25
t+886 (02)2299 3939 f+886 (02)2299 3237 www.sgs.tw
Member of the SGS Group
SGS Taiwan Ltd. 台灣檢驗科技股份有限公司
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx
and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Termse-Document.aspx. Attention is
drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s
findings at the time of its intervention only and within the limits of client’s instruction, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties
to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced, except in full, without prior written approval of the
Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested.
Page : 2 of 7
Test Report
No. : CE/2017/83612 Date : 2017/08/23
*CE/2017/83612*
MINMAX TECHNOLOGY CO., LTD.
NO. 18, SIN-SIN ROAD, AN-PING INDUSTRIAL DISTRICT, TAINAN 702, TAIWAN
Result
No.1
mg/kg With reference to IEC 62321-5 (2013) and
performed by ICP-AES.
2 n.d.
mg/kg With reference to IEC 62321-5 (2013) and
performed by ICP-AES.
2 6.36
mg/kg With reference to IEC 62321-4 (2013) and
performed by ICP-AES.
2 n.d.
mg/kg
With reference to IEC 62321-7-2 (2017) and
performed by UV-VIS.With reference to IEC
62321-5 (2013) and performed by ICP-AES.
8 n.d.
mg/kg - n.d.
mg/kg 5 n.d.
mg/kg 5 n.d.
mg/kg 5 n.d.
mg/kg 5 n.d.
mg/kg 5 n.d.
mg/kg 5 n.d.
mg/kg 5 n.d.
mg/kg 5 n.d.
mg/kg 5 n.d.
mg/kg 5 n.d.
mg/kg - n.d.
mg/kg 5 n.d.
mg/kg 5 n.d.
mg/kg 5 n.d.
mg/kg 5 n.d.
mg/kg 5 n.d.
mg/kg 5 n.d.
mg/kg 5 n.d.
mg/kg 5 n.d.
mg/kg 5 n.d.
mg/kg 5 n.d.
Hexabromodiphenyl ether
Decabromodiphenyl ether
MIXED ALL PARTS
Method
Octabromobiphenyl
Nonabromobiphenyl
Decabromobiphenyl
Pentabromobiphenyl
Hexabromobiphenyl
Heptabromobiphenyl
Unit
Tribromobiphenyl
Sum of PBBs
Monobromobiphenyl
Tribromodiphenyl ether
Test Result(s)
Tetrabromobiphenyl
Mercury (Hg)
Sum of PBDEs
Monobromodiphenyl ether
Dibromodiphenyl ether
PART NAME No.1
Octabromodiphenyl ether
Nonabromodiphenyl ether
Test Item(s)
Heptabromodiphenyl ether
Tetrabromodiphenyl ether
Pentabromodiphenyl ether
Dibromobiphenyl
Hexavalent Chromium Cr(VI) ()
Cadmium (Cd)
Lead (Pb)
MDL
With reference to IEC 62321-6 (2015) and
performed by GC/MS.