© Jack Sealey Limited
Original Language Version
INSTRUCTIONS FOR:
AIR FILTER/REGULATOR/LUBRICATOR UNITS
MODEL NO’S: SA2001.V2, SA2001/F.V2
SA2001/FR.V2, SA2001/L.V2, SA2001R
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT
CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL
INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions
and maintained properly, give you years of trouble free performance.
Refer to Instruction
Manual
1. SAFETY
p WARNING! Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when using this equipment.
p WARNING! Disconnect the equipment from the air supply before changing accessories, servicing or performing any maintenance.
 Keep the equipment clean and maintain it in good condition (use an authorised service agent).
Replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
p WARNING! Ensure that the correct air pressure is maintained and not exceeded.
p Keep air hose away from heat, oil and sharp edges. Check air hoses for wear before each use and ensure that all connections are
secure.
 DO NOT install in direct sunlight or near any other heat source.
 DO NOT direct air from the air hose at yourself, others or animals.
 Drain the air tank daily. Water in the air line will damage equipment.
When work is complete ensure that the air supply is turned off.
If in any doubt about correct installation of this equipment consult a competent engineer.
Suitable for most workshop air supply set-ups. Die-cast control heads with clear polycarbonate bowls. Regulator assembly features locking control
knob for pre-setting air pressure and large, easy-to-read pressure gauge. Filter is fitted with automatic drain tap. Lubricator includes oil/air mix
control and sight glass. Filter and Lubricator are fitted with protection bowl cage. (Model SA2001/FR.V2 and SA2001R are supplied with separate
wall brackets. SA2001.V2 has an integral bracket).
2. INTRODUCTION
SA2001.V2 SA2001/F.V2 SA2001/FR.V2 SA2001/L.V2 SA2001R
3. SPECIFICATION
Model No: ....................SA2001.V2 .......SA2001/F.V2 ........SA2001FR.V2 .......SA2001L.V2 .........SA2001R
Port Size: .....................3/8”BSP ..........3/8”BSP ............3/8”BSP ............3/8”BSP..............3/8BSP
Maximum Working Pressure: ......145psi ...........145psi .............145psi .............145psi ................145psi
Maximum Airow: ...............55cfm............48cfm..............70cfm ..............55cfm................. 80cfm
SA2001.V2,SA2001/F.V2, Issue:2 - 08/11/16
SA2001/FR.V2,SA2001/L.V2, SA2001R
4. INSTALLATION
4.1. Always ensure that components are installed in the air line in the correct ow direction. The ow direction is cast into the top casing of
each unit.
4.2. Install the lter (if separate) upstream from the regulator and the lubricator downstream from it.
4.3. To install SA2001.V2 x the integral mounting bracket to the wall.
4.4. To mount the SA2001/FR.V2 lter regulator and SA2001R regulator x the mounting bracket provided to the wall. Remove the mounting
bezel (g.1.8) from the neck. Place the neck through the mounting bracket and replace the bezel to clamp the mounting bracket.
4.5. To install the pressure gauge (g.1.2.), remove the blanking plug and screw in the gauge. PTFE tape may be required to achieve a good
seal.
4.6. The SA2001/F.V2 and SA2001/L.V2 can be installed in the pipe run, supported by the pipe. Ensure pipe is adequately supported.
Key to g.1:
1 Pressure Adjustment Knob
2 Pressure Gauge
3 Filter Drain
4 Bowl Release Catch
5 Oil Filler Plug
6 Oil Feed Sight Glass
7 Oil Feed Adjustment
8 Mounting Bezel
9 Mounting Bracket
g.1
5. OPERATION
6. ADDITIONAL FITTINGS
5.1. Regulator - The output pressure is controlled by the pressure adjustment knob (fig.1.1). Before pressurising air system for the first time lift
and rotate knob anticlockwise to remove any loading on the regulator spring. Pressurise the system and then rotate knob clockwise to set
the required output pressure, as shown on gauge (fig.1.2). When the required pressure is achieved lock knob by pushing down.
Note: For correct pressure setting always adjust upwards from a lower pressure. Therefore to reset from 90 to 70psi, for example, reduce
pressure from 90 to 60psi and then increase from 60 to 70psi.
5.2. Filter - The bowl will drain automatically each time the system pressure drops to zero. However; if the fluid level reaches the maximum
mark but the system is to remain pressurised the bowl can be manually drained by pushing the filter drain (fig.1.3) upward.
Note: the drain is designed to take a flexible tube so that the waste fluid can be piped away.
5.3. Lubricator - Remove filler plug (fig.1.5) and fill bowl with air tool oil. This can be done with air line pressurised.
With air flowing through the lubricator the oil delivery rate can be adjusted by means of the oil feed adjustment (fig.1.7) whilst watching
the feed rate through the sight glass (fig.1.6). The oil delivery rate will be increased or decreased automatically in line with the air flow.
The following fittings are available from your Sealey supplier:
SA1/1414 ..............................1/4”BSP-1/4”BSP male-male nipple
SA1/1212 ..............................1/2”BSP-1/2”BSP male-male nipple
SA1/3814F ......................... 3/8”BSP-1/4”BSP male-female reducer
SA1/1214F ............................1/2”BSP-1/4”BSP male-female reducer
SA1/1238F ............................1/2”BSP-3/8”BSP male-female reducer
Environmental Protection
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to
a recycling centre and disposed of in a manner which is compatible with the environment. When the product becomes completely
unserviceable dispose of it according to local regulations.
NOTE: It is our policy to improve products continually and as such we reserve the right to alter data, specifications and component parts without
prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
01284 757500
01284 703534
sales@sealey.co.uk
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park,
Bury St. Edmunds, Suffolk,
IP32 7AR
www.sealey.co.uk
© Jack Sealey Limited
Original Language Version
SA2001.V2,SA2001/F.V2, Issue:2 - 08/11/16
SA2001/FR.V2,SA2001/L.V2, SA2001R