www.L E D troni c s .com
© 2017 LEDtronics, Inc.
23105 Kashiwa Court, Torrance, CA 90505
Phone: (800) 579.4875 / (310) 534.1505
Fax: (310) 534.1424
E-mail: info@ledtronics.com
Website: http://www.ledtronics.com
INSTR-LDLGX24QU-0001-E / 09/2017
I
MPORTANT
S
AFETY
I
NSTRUCTIONS
Do not make or alter any open holes in an enclosure of
wiring or electrical components during lamp
installation.
For lamp replacement, use only lamps that function
without an external ballast.
THIS DEVICE IS NOT INTENDED FOR USE WITH
EMERGENCY EXITS.
Not for use with light dimmers.
LEDtronics suggests installing a luminaire disconnect
for protection when servicing lights.
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE
INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND
OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNING – Risk of re or electric shock. Wiring modication for bulb installation
requires knowledge of luminaire electrical systems. If not qualied, do not attempt
installation–Contact a qualied electrician.
WARNING – Risk of re or electric shock. The electrical rating of these products is
marked on the lamp; the installer must determine whether they have the correct
input voltage at the luminaire before installation.
WARNING – Risk of re or electric shock. Bypass the ballast (if present), apply
warning label, and install this LED bulb only in lampholders that have the
construction features and dimensions shown in the drawings.
WARNING – To prevent wiring damage or abrasion, do not expose wiring to edges
of sheet metal or other sharp objects.
Ballast-free LEDtronics bulbs have no
need for a longer plug.
OLD CFLs
LED
LEDtronics’
Universal
Base
replaces
these
uorescent
plug base
variants.
LEDtronics’
LDLG24QU
Series
Universal Base
No keytabs
Replaces
Larger GX24q sockets: LEDtronics LDL QU Series can be used in GX24q sockets that
formerly used CFL bulbs (and are directly powered to a pin on each plug side).
NOTE: No special electrician skills are necessary for
installation if: The bulb and the xture are of
compatible voltages, with matching plug and socket.
The xture is properly labeled as accepting only LED
bulbs, to never install with compact uorescents.
GX24q-1
(13W CFL)
GX24q-2
(18W CFL)
GX24q-3
(32W CFL)
GX24q-4
(42W CFL)
GX24q-5
(57W CFL)
GX24q-6
(70W CFL)
DANGER – RISK OF SHOCK: Disconnect Power Before Installation
LDLGX24QU-12WF
LDLGX24QU-10WF
Frosted Lens
Installation
Instructions
Omni-directional Light Beam
100 ~ 277 VAC
Page 1 of 2
PACKAGE INCLUDES: LED Lamp + Retrofit Caution Label + Installation Instructions
READ AND FOLLOW ALL PRECAUTIONS AND INSTALLATION
INSTRUCTIONS PRIOR TO INSTALLING THE LAMP
LEDtronics LED Lamps for GX24q 4-pin Bases and Retrofit Modifcations
that Convert Compact Fluorescent Fixtures (CFL)
Lamp is intended only
for installations where
lamp is oriented
vertically, with base
inserted either up or
down.
wirenut
(user
supplied)
On the replacement socket, connect one wire of the power
source with a wirenut to a lead from EITHER side of the
(Capped
unused
wire)
plug cavity
(Unused
wire)
A
C
B
Connect the remaining power wire with a wirenut to
EITHER terminal on the OTHER SIDE of the plug cavity.
A
C
B
Apply the LEDtronics cautionary label where it can be seen by
someone installing or maintaining a bulb.
D
The GX24Q-base lamp xture that does not use a ballast should
have a readily visible marking or label stating to the e���ect that
“This luminaire has been modied and can no longer operate
the originally intended CFL lamp” or “This xture is intended
for LED lamps only. Never plug in a uorescent lamp.”
If no lamp-modication notice is present, ax the LEDtronics
LED Lamp Replacement Marking label where readily visible
by a user during maintenance or relamping.
If the lamp xture has been modied for LED lamps
and does not use a CFL BALLAST
Does the GX24q socket have an integrated ballast?
www.L E D troni c s .com
© 2017 LEDtronics, Inc.
A caution label should be visible to the bulb installer
warning against installing uorescent (CFL) bulbs in the xture.
Plug the LED lamp into the socket with LEDs facing in the
correct direction.
Close xture and restore power.
then . . .
If the socket has an integrated ballast,
replace it with a socket without a ballast.
INSTR-LDLGX24QU-0001-E / 09/2017
plug cavity ( )
(The sockets and
wiring diagram are
purely diagrammatic.)
Unused Wire Lead (2×)
cut
cut
cut
cut
(The wiring diagram and
components are purely diagrammatic.)
(OLD
LAMP)
(LEDTRONICS
LAMP)
To VAC Line Voltage
To VAC Line Voltage
Bypass
Ballast
4
1
2b
2a
Modications needed if the lamp xture USES A BALLAST
Remove old
CFL lamp
1.
Remove or bypass ballast
(and starter, if present)
– 2a Cut the existing lampholder leads
to separate ballast from lamp.
– 2b Use wire nuts to connect
the power leads to socket.
2.
Install LED lamp4.
Close xture and restore power5.
Place provided caution label in a visible location on the xture
3.
1.
2.
3.
Connect one power lead to one
side of the plug cavity with wire
nut.
Connect the
other
power lead
on the
other side
of the plug
cavity.
(Installer supplies
wire nuts or code-
compliant
connectors)
Plug
Cavity
Determine that the light beam direction of the right-angled
bulb illuminates to the best advantage in the housing.
The xture housing should not be totally enclosed and
should allow any bulb heat to escape. The ambient
temperature environment of the bulb should be no greater
than 122°F [50°C].
Does the xture housing have the clearance to accept
the LEDtronics bulb and allow light to beam unimpeded?
Page
2 of 2
If a grounding wire is present, assure it is connected to a suitable ground point
Installer should not disconnect existing wires from lampholder terminals.
Instead installer should cut existing lampholder leads away from the
lampholder and make new electrical connections to lampholder lead wires by
employing applicable connectors.
2b
Series LDLGX24QU-10W,
LDLGX24QU-12W
4.42 [112]
6.62 [168]
Ø1.57 [Ø40]
LED LIGHT BEAM
GX24q Socket
The two
power input
lines connect
to their
respective
pin on each
side of the
plug
Dimensions in inches [mm]
Only for installa-
tions where lamp
is oriented
vertically, with
base inserted
either up or down