INSTRUCTIONS FOR
AIR REGULATOR, FILTER, LUBRICATOR RANGE
MODEL NO: SA206, SA206FR, SA206F, SA206L
SA206R, SA206FRAD, SA206FAD
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY
WARNING! Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when using this equipment.
WARNING! Disconnect the equipment from the air supply before changing accessories, servicing or performing any maintenance.
9 Keep the equipment clean and maintain it in good condition (use an authorised service agent).
9 Replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
WARNING! Ensure that the correct air pressure is maintained and not exceeded.
9 Keep air hoses away from heat, oil and sharp edges. Check hoses for wear before each use and ensure that all connections are secure.
8 DO NOT direct air from the air hose at yourself, others or animals.
9 Drain the compressor air tank daily. Water in the air line will damage your equipment.
9 When work is complete ensure that the air supply is turned off.
2. INTRODUCTION
Suitable for industrial workshop air supply set-ups where high volume applications are required. Regulator assemblies feature locking control
knob for pre-setting air pressure and large easy-to-read pressure gauge. Filters available with manual or auto drain facility with female
1/8”BSP outlet. Lubricator includes oil/air mix control and sight glass. Filter and lubricator are fitted with metal bowl cages for protection.
SA206, SA206FR, SA206FRAD and SA206R supplied with mounting bracket.
3. SPECIFICATION
SA206/206FR/206F/206L/206R/206FAD/206FRAD
| Issue 4 04/05/17
Original Language Version
© Jack Sealey Limited
Refer to
instructions
Filter/Lubricator/Regulator - SA206
Max. inlet pressure ....................150psi (10.3 bar)
Max. outlet pressure ....................125psi (8.6 bar)
Max. flow rate @ 100psi (6.9 bar) ................105cfm
Filter .....................................25 micron
Lubricant ........Sealey Air Tool Oil - ATO/500 or ATO/1000
Ports-Inlet ..................................1/2”BSP
Outlet .................................1/2”BSP
Gauge ................................1/4”BSP
Lubricator - SA206L
Max. inlet pressure ....................150psi (10.3 bar)
Max. outlet pressure ....................125psi (8.6 bar)
Max. flow rate @ 100psi (6.9 bar) ................175cfm
Lubricant ........Sealey Air Tool Oil - ATO/500 or ATO/1000
Ports-Inlet ..................................1/2”BSP
Outlet .................................1/2”BSP
SA206
SA206FR & SA206FRAD
SA206R
SA206F & SA206FAD
SA206L
4. CONTENT & INSTALLATION
4.1. Confirm that all items are present and undamaged. If any parts are missing or damaged please contact the supplier.
SA206 - Combined filter, regulator with gauge, lubricator and mounting bracket.
SA206FR - Combined filter, regulator with gauge and mounting bracket.
SA206F - Filter.
SA206L - Lubricator.
SA206R - Regulator with gauge and mounting bracket.
SA206FAD - Filter with Auto Drain,
SA206FRAD - Combined filter with auto drain, regulator
with gauge and mounting bracket.
4.2. Fig.1 shows a typical air line installation. The filter is located
upstream of the regulator - unless combined, as in SA206
and SA206FR - and the lubricator downstream.
4.3. Filter/regulator - Install using the mounting bracket provided.
Before connecting system piping ensure that gauge is visible,
unused gauge port is sealed with plug provided and that flow
direction arrow matches system air flow.
Filter and Lubricator - Install into air piping or connect directly to bracket mounted regulator using fittings provided. Always check that
flow arrows are correct and that filter is upstream, and lubricator downstream, of regulator.
Note: To ensure air-tight joints, use PTFE tape.
5. OPERATION
5.1. Regulator - The output pressure is controlled by the knob. Before pressurising the air system for the first time, pull out and rotate
the knob anticlockwise to remove any loading on the regulator spring. Pressurise the system and then rotate knob clockwise to set
required output pressure, as shown on gauge. When the required pressure is achieved push in knob to prevent inadvertent
adjustment.
Note: For correct pressure setting always adjust up from a lower pressure. Therefore to reset from 90 to 70psi for example, reduce
pressure from 90 to 60psi and then increase to 70psi.
5.2. Filter - The bowl should be drained regularly to prevent an excessive build-up of water/oil. Pull down the drain valve at the bottom of
the bowl, allow to drain and then release. Drain valve has female 1/8” BSP outlet. (SA206FRAD and SA206FAD have Auto drain
feature. When pressure in bowl drops, float valve opens and drains condensation. Drain valve has male 1/8” BSP outlet).
5.3. Lubricator - Remove the filler plug (fig.2.A) and fill bowl up to max. level, with air tool oil. This can be done with the air line pressurised.
With air flowing through the lubricator the oil delivery rate can be adjusted by screw (fig.2.C) whilst watching the drip rate
through the sight dome (fig.2.B). The oil delivery rate will automatically increase or decrease in line with the air flow.
5.4. Both the filter and the lubricator are supplied with a metal bowl guard. To remove the guard, pull down the latch (fig.3.D) and rotate
the guard until either of the two pairs of lines (fig.3.E) on the guard align with the similar marks (fig.3.F) on the head. The guard can
now be removed.
To refit, slide the top of the guard into the head with the guard and head markings aligned, and the rotate the guard so that the latch
aligns with the marks on the head. The latch will lock into place.
Regulator - SA206R
Max. inlet pressure ....................150psi (10.3 bar)
Max. outlet pressure ....................125psi (8.6 bar)
Max. flow rate @ 100psi (6.9 bar) ................210cfm
Ports-Inlet ..................................1/2”BSP
Outlet .................................1/2”BSP
Gauge ................................1/4”BSP
Filter - SA206F, SA206FAD
Max. inlet pressure ....................150psi (10.3 bar)
Max. outlet pressure ....................125psi (8.6 bar)
Max. flow rate @ 100psi (6.9 bar) ................140cfm
Filter .....................................25 micron
Ports-Inlet ..................................1/2”BSP
Outlet .................................1/2”BSP
Auto drain ............................SA206FAD only
WARNING! Filter and lubricator bowls are manufactured
from polycarbonate and must not be used at temperatures
over 125°F (52°C) or for pressures over 218psi (15 bar).
Polycarbonate can be damaged and may fail if exposed to
certain solvents either internally or externally - strong
alkalies, compressor oils containing aromatic hydrocarbons
or fire retardant oils, or the fumes of any of these. Clean
with warm water only.
Filter/Regulator - SA206FR, SA206FRAD
Max. inlet pressure ....................150psi (10.3 bar)
Max. outlet pressure ....................125psi (8.6 bar)
Max. flow rate @ 100psi (6.9 bar) ................140cfm
Filter .....................................25 micron
Ports-Inlet ..................................1/2”BSP
Outlet .................................1/2”BSP
Gauge ................................1/4”BSP
Auto drain .......................... SA206FRAD only
g.1
g.2
g.3
SA206/206FR/206F/206L/206R/206FAD/206FRAD
| Issue 4 04/05/17
Original Language Version
© Jack Sealey Limited