Thank you for purchasing the Sequence Creation Software SD011-
PCR-LE Wavy for PCR-LE.
SD011-PCR-LE Wavy for PCR-LE is a software application that en-
ables you to create and execute sequences on Kikusui PCR-LE and
PCR-LE2 Series AC power supplies from a PC.
You can use a mouse to easily create and edit sequences.
During sequence execution, the software displays the point of ex-
ecution.
You can save the monitored voltage, current, and power values to
les.
The software displays monitored data as a real-time monitor graph.
This setup guide is included in the Wavy for PCR-LE package. For the
operating procedures, see the help le or the operation guide in PDF
format (included in the CD-ROM). You can view the PDF file using
Adobe Reader.
Product versions that this guide covers
This guide applies to versions 5.6x of SD011-PCR-LE Wavy for PCR-
LE. To check the Wavy for PCR-LE version, on the Help menu, click
About Wavy.
Related equipment versions
This software is compatible with PCR-LE and PCR-LE2 Series AC
power supplies with rmware version 4.3 and later. The rmware ver-
sion appears on the front control panel when the AC power supply is
turned on.
Related manuals
For details about the AC power supply, see the PCR-LE or PCR-LE2
Series Operation Manual. For details on the communication interface,
see the PCR-LE or PCR-LE2 Series Communication Interface Manual.
Trademarks
Microsoft and Windows are either registered trademarks or trademarks
of Microsoft Corporation in the United States and/or other countries.
Intel and Pentium are registered trademarks of Intel Corporation or its
subsidiaries in the United States and other countries.
All company names and product names used in this manual are trade-
marks or registered trademarks of their respective companies.
Software license agreement
Use this software product under the conditions set forth in “Software
License Agreement” that is included in the product CD-ROM.
Copyrights
The contents of this guide may not be reproduced, in whole or in part,
without the prior consent of the copyright holder. The specications of
this product and the contents of this guide are subject to change with-
out prior notice.
Copyright© 2012 Kikusui Electronics Corporation
Safety Precautions
Before you use Wavy for PCR-LE, read the operation manual of the Wavy for PCR-LE or PCR-LE2 Series AC power supply that you intend to use
Wavy for PCR-LE to control, and be sure to make proper connections and handle the device properly. Improper connections or handling can lead
to serious accidents, injury, and re.
System Requirements
Part No. Z1-005-502, IB024553
Mar 2019
Ver 5.6x
Sequence Creation and Control Software Setup Guide
SD011-PCR-LE Wavy for PCR-LE
http://www.kikusui.co.jp/en
Website
KIKUSUI ELECTRONICS CORP.
1-1-3 Higashiyamata, Tsuzuki-ku, Yokohama,
224-0023, Japan
Tel: +81-45-482-6353 Fax: +81-45-482-6261
Installation
You need to log on as an administrator to install the software.
Installing the VISA library
To control the PCR-LE Series, a VISA library must be installed on your
PC.
VISA (Virtual Instrument Software Architecture) was developed by
the VXIplug&play Systems Alliance. It is the standard specication for
measurement instrument connection software. You need one of the
following VISA libraries.
NI-VISA by National Instruments Corporation (Ver. 5.0.3 or later)
Agilent VISA by Agilent Technologies (Agilent IO Libraries Suite
15.1 or later)
KI-VISA version 5.0.1 or later
KI-VISA is a VISA library developed by Kikusui Electronics Corpora-
tion that supports the IVI VISA 5.0 specications. You can download
the most recent version of this library from the Kikusui Electronics Cor-
poration website (http://www.kikusui.co.jp/en/download/).
If NI-VISA or Agilent VISA is already installed on your PC, you do not
need to install KI-VISA.
1
Load the CD-ROM into the CD-ROM drive.
A setup start window appears. If a setup start window does not
appear, double-click the AutoRun.exe le on the CD-ROM.
2
Click Install under “1. The installation of the VISA li-
brary.”
The installation of the VISA library begins. If a VISA library has
already been installed, the installed VISA library and its version
are displayed. Do not install multiple VISA libraries on the same
PC.
Installing Wavy for PCR-LE
1
Load the CD-ROM into the CD-ROM drive.
A setup start window appears. If a setup start window does not
appear, double-click the Setup.exe le on the CD-ROM.
2
Click Install under “2. The Installation of WAVY.”
3
Proceed with the installation according to the instruc-
tions on the screen.
4
Click Close.
Uninstalling Wavy for PCR-LE
In Control Panel, select Programs and Features, and remove Kikusui
SD011-PCR-LE (Wavy for PCR-LE Ver.5.5.x.x).
Core2 or better
Windows 10 or Windows 7
At least 2 GB of RAM.
10 GB or more of free hard-disk space
A display that supports a resolution of 1024×768 or higher (DPI: 96)
CD-ROM drive
Mouse
RS232C, GPIB, USB, or LAN (depending on the interface that you
want to use)
Install more RAM if you intend to perform long tests. We recommend
you install more than 4 GB RAM.
A VISA library that supports the IVI VISA 5.0 specications must be
installed in your PC.
The software may not function properly if you use a USB serial con-
verter to connect to an RS232C interface.
Connecting the PCR-LE to your PC
For details on connecting the PCR-LE to your PC, see the PCR-LE Series user’s
manual and “Interface Setup” in the Communication Interface Manual. Cables
are not included.
RS232C
Use a D-sub, 9-pin, female-to-female AT crossover cable.
The PCR-LE Series RS232C port is a DB9P connector.
GPIB
Use a standard IEEE-488 cable.
USB
Use a standard USB cable.
LAN
Use a standard LAN cable (category 5 and straight) to connect the PCR-LE to a
network hub or router. Use a crossover cable when making a direct connection.
Conguring the PCR-LE
1
Make sure that the PCR-LE output is o.
2
Press CONFIG (SHIFT+OPR MODE) to select COM-I/F.
3
Press the ▲▼ keys to select TYPE, and then select the commu-
nication interface.
4
Press the ▲▼ keys to move the selection frame to the item that
you want to set, and then use the function keys or rotary knob to
select the item’s value.
For LAN, set DHCP and AUTO IP to “on.”
5
Turn o the PCR-LE, and turn it back on.
The settings are applied.
If you want to use the LAN interface with a xed IP address, congure the set-
tings from the Web interface to the PCR-LE Series (search for the VXI-11 mea-
surement instrument from the application supplied by the VISA vendor and click
the link that the search returns). After setting the IP address, set DHCP and
AUTO IP to “o” on the COM-I/F screen in the CONFIG settings. Then, turn o
the PCR-LE, and turn it back on.
Starting Wavy for PCR-LE
Disable the Windows power-saving mode and screen saver. Also, avoid using
other applications with Wavy for PCR-LE.
If you are using a PC that has advanced power management (APM) or sleep
mode, disable these features.
When you change the DPI setting, the display may not appear properly depend-
ing on the resolution.
To start Wavy for PCR-LE, on the taskbar, click Start, All Programs, Kikusui,
SD011-PCR-LE, and then Wavy for PCR-LE.
After you start Wavy for PCR-LE, rst congure
the interface.
On the Sequence menu, click Interface, and then
click the interface that you want to use.
Conguring the RS232C interface
1
Set the COM port.
2
Set the baudrate.
3
Click Test.
Check that the software can communicate
properly with the PCR-LE.
Conguring the GPIB interface
1
Select the GPIB address.
2
Click Test.
Check that the software can communicate
properly with the PCR-LE.
Conguring the USB interface
1
Set the serial number.
Select the serial number from the list, or
enter it. The serial number is displayed on
the rear panel of the PCR-LE.
2
Click Test.
Check that the software can communicate
properly with the PCR-LE.
Conguring the LAN interface
1
Set the IP address.
Select the IP address from the list, or en-
ter it. You can view the IP address on the
COM-I/F screen in the PCR-LE’s CONFIG
settings.
2
Click Test.
Check that the software can communicate
properly with the PCR-LE.
If you are not using a fixed IP address, the IP
address of the PCR-LE may change. If the PC
stops recognizing the PCR-LE, check the IP ad-
dress on the COM-I/F screen in the PCR-LE’s
CONFIG settings, and then set the IP address in
the software again.
Conguring the interface
How to Use Wavy for PCR-LE
For information on how to use Wavy for PCR-LE, see the help le or the PDF. You can view the PDF le (on the CD-ROM) using Adobe
Reader.
Executing sequences
1
On the Sequence menu, click Sequence Creation-
Mode.
In the Sequence Creation Mode dialog box, set the wiring
method, unit of time, output voltage mode, output voltage
range, and frequency.
2
Create steps.
You can create steps in the Graph window using the mouse
or in the Worksheet window by entering values directly.
You can also congure protection functions.
After you have created the steps, save them to a file. You
can also directly overwrite the data of a file that you have
saved.
3
On the Sequence menu, click Transfer.
In the Transfer dialog box, set the repetition count, and ex-
ecute the transfer.
Select the Write Wave check box to transfer the arbitrary
waveform data at the same time.
4
On the Sequence menu, click Run.
In the Run dialog box, run the sequence.
In the Run dialog box, you can display the setting graph and
the real-time monitor graph. During execution, the repetition
count, the step position, and the elapsed time are displayed.
The voltage, current, and power values are displayed in ac-
cordance with the monitoring conguration.
You can save the monitored data to a le.
Controlling the PCR-LE directly
You can use Wavy for PCR-LE to directly control the Wavy for
PCR-LE.
Using commands to control the PCR-LE
You can enter
PCR-LE or PCR-LE2 Series
commands in Wavy for
PCR-LE to control the PCR-LE remotely.
Specications
Operation modes: AC voltage, DC voltage, and AC+DC voltage
Number of signicant decimal places: 3
1
Monitoring: Output current, output voltage, and output power
Monitoring interval
2
: 200 ms to 600 000 ms (0.2 s to 600 s) for
single-phase, two-wire
500 ms to 600 000 ms (0.5 s to 600 s) for
single-phase, three-wire and three-phase
Total number of steps: 600
Step interval (execution time) setting range
Unit Value
ms (milliseconds) 0.1 to 10000.0
s (seconds) 0.001 to 1000.000
min (minutes) 0.1 to 1000.0
h (hours) 0.1 to 1000.0
1 This varies depending on the range setting of the connected
PCR-LE or PCR-LE2 Series.
2 The accuracy depends on the PC environment that you are using.
.