DC Power Supply
Constant voltage/constant current, three types of 350 W, 700 W, and 1000 W,
Max Voltage (10V to 500V) 24 models
With digital communication functions and a power-factor correction circuit
Controlling via USB, GPIB or RS-232C can be supported by an option
Variable-switching Regulated
DC Power Supplies
PAS Series
0.98
EQUIPPED WITH A POWER-FACTOR
CORRECTION CIRCUIT
POWER
FACTOR
MAX
500V
2
Analog read-back function
Monitor output (voltage output)
Output voltage monitoring
Output current monitoring
Status signal output (contact signal output)
CV mode signal, CC mode signal, Output ON
signal, Alarm signal, POWER ON signal
The PAS Series consists of sophisticated variable-switching
'&SRZHUVXSSOLHVWKDWUHÀQHDQGDGGWRWKHDGYDQFHVRI
our conventional PAK-A Series. While the cabinet size
remains unchanged from conventional models, the PAS Series
LQFRUSRUDWHVDKLJKHIÀFLHQF\VZLWFKLQJFLUFXLWDQGDSRZHU
IDFWRUFRUUHFWLRQFLUFXLWWRPHHWWKHQHHGVRIWRGD\VXVHUV7KH
PAS Series also provide Kikusui-developed digital
communication functions (TP-BUS, Twisted Pair Bus) with
FRPELQDWLRQRIXVLQJRSWLRQDO3RZHU6XSSO\&RQWUROOHU
3,$6HULHV7KLVVHULHVFDQKDQGOHSRZHUVXSSO\V\VWHPV
UDQJLQJIURPVPDOOVFDOHWZRXQLWVWRODUJHVFDOHV\VWHPVXS
to 448 units when used in combination with GPIB) at low cost.
,WLVSRVVLEOHWREXLOGXSWKHV\VWHPE\XVLQJ3RZHU6XSSO\
Controller PIA4800 Series that can control the Power Supplies
ORFDWHGDWWKHIDFWRU\IURPWKHRIÀFH3&IRUWKHGLVWDQFHXSWR
P$VVKRZQLQWKHÀJXUH
Attractive new design
7KHG\QDPLF QHZFRORU VFKHPH RI WKH 3$66HULHV
IHDWXUHVDJUD\ZKLWHEDVHZLWKDIURQWORXYHULQ
vibrant blue. Models in this series are controlled
with a multifunction dial and feature a high-
EULJKWQHVVIRXUGLJLWLQGLFDWLRQGLVSOD\XQLW'LVSOD\
digits provide readings down to 10mV/1 mA, and a
RXWSXWSRZHU:GLVSOD\IXQFWLRQLVDOVRSURYLGHG
7KHHQGUHVXOWLVLPSURYHGRSHUDELOLW\DQGYLVLELOLW\
Handling margin testing with capacity
The maximum rated output voltage of conventional
SURGXFWVLVW\SLFDOO\DUDQJHFRQVLVWLQJRI9
9 9 9 D QG 9 7 K H 3$6 6 H U L H V R I IHU V D
m a x i m u m r a t e d o u t put v olt a g e o f 10 V, 20 V, 4 0 V,
9 99 9DQG9LQUHVSRQVHWR
changes in the voltage ranges required for margin
testing due to the conversion of equipment such as
DC-DC converters, batteries, automobile electrical
components, and motor-operated tools to high
YROWDJHRUODUJHFDSDFLW\IRUPDWV7KLVDOORZVWKH
3$66HULHVWRKDQGOHWHVWVDWRI99
RUDWRI99ZLWKFDSDFLW\WRVSDUH
External analog control functions
Constant-voltage/constant-current output control
function
Output control based on external voltage (0 to 10 V)
2XWSXWFRQWUROEDVHGRQH[WHUQDOUHVLVWDQFHWRN
Output ON/OFF control function
External contact-based output ON/OFF control
Power switch control function
External contact-based power switch OFF control
TYPE I (350W type) TYPE III (1000W type) TYPE II (700W type)
Four-digit indication display unit
Multifunction dial
Supporting universal AC input
Equipped with a power-factor
correction circuit
High power conversion efficiency of
75%
(TYP.)
Equipped with digital communication
functions
Equipped with digital communication functions and a power-
Introducing 15 new models!!
MAX
500V
[Notice]
Because a noise filter is used for the primary
input for the PAS series, the leakage breaker,
etc. may be activated, depending on the
environment of the input power, when using
multiple quantities of them at the same time.
Therefore, we provide models called “PAS
Series, LLC model” for customers who are
planning to use multiple units. If you have any
questions, please contact our sales for the
details.
Please be noted that LLC model is not