Translation of the original instructions
1 Applicable documents
All available documents for the product èwww.festo.com/pk.
Document Product Contents
Description Terminal CPX System, Assembly, Installation, Com
missioning
Description Valve terminal MPALVI
Description Valve terminal MPAF
Description Valve terminal MPAS
System, Assembly, Installation, Com
missioning, conversion, disassembly
Tab. 1
2 Safety
2.1 Safety instructions
Only assemble the product on components that are in a condition to be safely
operated.
Observe the handling specifications for electrostatically sensitive devices.
Plan sufficient space:
Enable heat dissipation by air circulation è 1 Applicable documents
Ensure that the connections are accessible
Requirements for the mounting surface:
torsionfree operation of the product
support of the weight and other forces occurring during operation
2.2 Intended use
The CPX terminal with valve terminal MPA1 is referred to as CPX terminal1 in
this instruction manual.
Product Use
CPX terminal1 Control of pneumatic actuators. Query of the sensors.
Mounting
2/3/5/6/8/aJ
Additional wall mounting of the valve terminal1.
Tab. 2
3 Product range overview
3.1 Scope of delivery
1
Terminal
CPX
with
Valve terminal
MPA
Fig. 1
Wall mounting
Mounting for CPX modules (plastic):
2
Mounting
CPXBGRW...
Fig. 2
Mounting for CPX modules (metal):
3
Mounting bracket
CPXMBGRW...
4
ScrewM3
(threadcutting)
Fig. 3
Mounting for MPALVI modules
5
Mounting bracket
VMPALBD
Fig. 4
Mounting for MPAF modules
6
Mounting bracket
VMPAFBGRW...
7
ScrewM4
(threadcutting)
Fig. 5
Mounting for MPAS proportionalpressure regulator
8
Mounting bracket
VMPABG
9
ScrewM3
(threadcutting)
Fig. 6
Mounting for MPAS intermediate supply (pneumatic supply plate)
10
Mounting bracket
VMPABGRW...
11
ScrewM3
(threadcutting)
Fig. 7
3.2 Not included
H-rail mounting
12
Hrail(1x)
EN 60715  35x7.5 or 35x15
Fig. 8
Mounting CPXCPABGNRH
13
Screw(3x)
14
Clamping element(3x)
Fig. 9
Mounting VMPAFFBBGNRH
8085254
CPX, CPX-M, MPAL-VI, MPA-F, MPA-S
Terminal CPX / Valve terminal MPA
8085254
201901a
[8085256]
Instructions|Assembly
Festo AG & Co. KG
Ruiter Straße 82
73734 Esslingen
Germany
+49 711 3470
www.festo.com
15
Clamping element MPAF(1x)
16
Screw(1x)
17
Screw(2x)
18
Clamping element CPA(2x)
Fig. 10
4 Mounting
4.1 Wall mounting
4.1.1 Check positions of the mountings
Mountings are preassembled depending on the configuration.
CPX modules: counting direction from the end plate[V]
MPA modules: orientation from the mounting points of the adapter plate[W]
Fig. 11
1. Check positions of the preassembled mountings and correct if required.
2. Assemble by step 3, 4, 5, 6 or 7 depending on the mounting:
3. Positions of mounting2 with CPX modules (plastic)
Number of modules Mounting between the modules
2 and 3 5 and 6 8 and 9
1…2
3
1)
4…5
6…8
9…10
1) This mounting is not required in combination with MPAL valve terminals.
Tab. 3
4. Positions of mounting3 with CPX modules (metal)
Number of modules Mounting to the modules
2 3 4 6 7
1…3
4
5…6
7
8
9…10
Tab. 4
5.
Positions of the mounting5 with MPALVI valve terminal ³ 200 mm
every 130 mm
6.
Positions of the mounting6 with MPAF valve terminal ³ 300 mm
every 250 mm on subbase
7.
Positions of the mounting8/aJ with MPAS valve terminal ³280 mm
a mounting every 130 mm:
8 on MPAS proportional pressure regulator or
aJ on MPAS intermediate supply
With MPAS valve terminals size 14 in
horizontal or vertical suspended position from mounting point [V] mount
a MPAS intermediate supply after every third module.
horizontal recumbent position from mounting point [W] mount a MPAS
intermediate supply after every second module.
SG2: total length of valve terminal £ 430 mm
SG1: total length of valve terminal > 430 mm
4.1.2 Assemble mountings
4.1.2.1 Mounting[2] on CPX modules (plastic)
Fig. 12
1. Press mounting2 inclined into the back of the modules[A].
2. Tilt mounting2 until it catches.
3. Install additional mounting2 opposite.
4.1.2.2 Mounting[3] on CPX modules (metal)
For CPX modules (metal) without system supply, the mounting3 can be
assembled on both sides of the module.
Fig. 13
1. Place mounting3 on the module[B].
2. Tighten4 screws. When screwing in again, use the threads already present.
Tightening torque: 1.5Nm ± 10 %
4.1.2.3 Mounting[5] on MPAL-VI modules
Fig. 14
1. Press mounting5 inclined into the back of the modules[C].
2. Tilt mounting5 until it catches.