Translation of the original instructions
1 Applicable documents
All available documents for the product èwww.festo.com/pk.
Document Product Contents
Description Valve terminal MPAL-VI
Description Valve terminal MPA-F
Description Valve terminal MPA-S
System, Assembly, Installation, Com-
missioning, conversion, disassembly
Tab. 1
2 Safety
2.1 Safety instructions
Only assemble the product on components that are in a condition to be safely
operated.
Observe the handling specifications for electrostatically sensitive devices.
Plan sufficient space:
Enable heat dissipation by air circulation è 1 Applicable documents
Ensure that the connections are accessible
Requirements for the mounting surface:
torsion-free operation of the product
support of the weight and other forces occurring during operation
2.2 Intended use
Product Use
Valve terminal1 Control of pneumatic actuators. Query of the sensors.
Mounting
2/3/5
Additional wall mounting of the valve terminal1.
Tab. 2
3 Product range overview
3.1 Scope of delivery
1
Valve terminal
MPA
Fig. 1
Wall mounting
Mounting for MPAL-VI modules
2
Mounting bracket
VMPAL-BD
Fig. 2
Mounting for MPA-F modules
3
Mounting bracket
VMPAF-BG-RW-...
4
ScrewM4
(thread-cutting)
Fig. 3
Mounting for MPA-S intermediate supply (pneumatic supply plate)
5
Mounting bracket
VMPA-BG-RW-...
6
ScrewM3
(thread-cutting)
Fig. 4
3.2 Not in scope of delivery
H-rail mounting
7
H-rail(1x)
EN 60715 - 35x7.5 or 35x15
Fig. 5
Mounting CPX-CPA-BG-NRH
8
Screw(3x)
9
Clamping element(3x)
Fig. 6
4 Mounting
4.1 Wall mounting
4.1.1 Check positions of the mountings
Orientation from mounting points of the electric controller[V].
Fig. 7
1. Check positions of the pre-assembled mountings and correct if required.
2. Assemble by step 3, 4 or 5 depending on the mounting:
3.
Positions of the mounting2 with MPAL-VI valve terminal ³ 200 mm
every 130 mm
4.
Positions of the mounting3 with MPA-F valve terminal ³ 300 mm
every 250 mm on sub-base
5.
Positions of the mounting5 with MPA-S valve terminal ³ 280 mm
every 130 mm one mounting5 on MPA-S intermediate supply
With MPA-S valve terminals size 14 in
horizontal or vertical suspended position from mounting point [V] mount
a MPA-S intermediate supply after every third module.
horizontal recumbent position from mounting point [V] mount a MPA-S
intermediate supply after every second module.
SG2: total length of valve terminal £ 430 mm
SG1: total length of valve terminal > 430 mm
8085245
MPAL-VI, MPA-F, MPA-S
Valve terminal MPA
8085245
2019-01a
[8085247]
Instructions|Assembly
Festo AG & Co. KG
Ruiter Straße 82
73734 Esslingen
Germany
+49 711 347-0
www.festo.com
4.1.2 Assemble mountings
4.1.2.1 Mounting[2] on MPAL-VI modules
Fig. 8
1. Press mounting2 inclined into the back of the modules[A].
2. Tilt mounting2 until it catches.
4.1.2.2 Mounting[3] on MPA-F modules
Fig. 9
1. Place mounting3 on the module[B].
2. Tighten4 screws. When screwing in again, use the threads already present.
Tightening torque: 4Nm ± 20 %
4.1.2.3 Mounting[5] on MPA-S intermediate air supply
Fig. 10
1. Place mounting5 on the module[C].
2. Tighten6 screws. When screwing in again, use the threads already present.
Tightening torque: 1.5Nm ± 10 %
4.1.3 Overview of the mounting points
Select screws suitable for the installation situation.
4.1.3.1 Mounting points of the MPAL-VI valve terminal
Fig. 11
Mounting point Screw size Number
[D] M6 2x
[E] M6 1x every 2
[F] M6 2x
Tab. 3
4.1.3.2 Mounting points of the MPAL-F valve terminal
Fig. 12
Mounting point Screw size Number
[D] M6 2x
[G] M6 1x every 3
[F] M6 2x
Tab. 4
4.1.3.3 Mounting points of the MPAL-S valve terminal
Fig. 13
Mounting point Screw size Number
[D] M6 2x
[H] M6 1x every 5
[F] M6 2x
Tab. 5
4.2 H-rail mounting
A screw8 and a clamping element9 are left over.