AL4RPV-50, HELIAX® Plenum Rated Air Dielectric Coaxial Cable,
corrugated aluminum, 1/2 in, Red PVDF jacket
l This product is part of the CommScope Wired for WirelessThis product is part of the CommScope Wired for Wireless® ® Solution Solution
Product Classification
Brand
HELIAX
®
Product Series
AL4
-
50
Product Type
Air coaxial cable
Construction Materials
Jacket Material
PVDF
Dielectric Material
PE spline
Flexibility
Standard
Inner Conductor Material
Copper
-
clad aluminum wire
Jacket Color
Red
Outer Conductor Material
Corrugated aluminum
Dimensions
Nominal Size
1/2 in
Cable Weight
0.21 kg/m|0.14 lb/ft
Diameter Over Jacket
15.748 mm|0.620 in
Inner Conductor OD
4.5720 mm|0.1800 in
Outer Conductor OD
14.046 mm|0.553 in
Electrical Specifications
Cable Impedance
50 ohm ±2 ohm
Capacitance
76.0 pF/m|23.0 pF/ft
dc Resistance, Inner Conductor
1.570 ohms/km|0.480 ohms/kft
dc Resistance, Outer Conductor
1.570 ohms/km|0.480 ohms/kft
dc Test Voltage
4000 V
Inductance
0.190
µ
H/m|0.058
µ
H/ft
Insulation Resistance
100000 Mohmskm
Jacket Spark Test Voltage (rms)
5000 V
Operating Frequency Band
1
6000 MHz
Peak Power
40.0 kW
Power Attenuation
2.325
Pulse Reflection
0.5%
Velocity
88%
AL4RPV
-
50R
page 1 of 4
April 12, 2019
©2019CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the
most current information. Revised: December 22, 2018
Environmental Specifications
Installation Temperature
-
5 °C to +60 °C (+23 °F to +140 °F)
Operating Temperature
-
20 °C to +85 °C (
-
4 °F to +185 °F)
Storage Temperature
-
20 °C to +85 °C (
-
4 °F to +185 °F)
General Specifications
Ordering Note
CommScope
®
standard product (Global)
Mechanical Specifications
Bending Moment
6.8 N
-
m|5.0 ft lb
Fire Retardancy Test Method
NFPA 262/CATVP/CMP
Flat Plate Crush Strength
1.4 kg/mm|80.0 lb/in
Minimum Bend Radius, Multiple Bends
127.00 mm|5.00 in
Minimum Bend Radius, Single Bend
64.00 mm|2.50 in
Number of Bends, minimum
15
Tensile Strength
79 kg|175 lb
Note
Performance Note
Values typical, unless otherwise stated
Standard Conditions
Attenuation, Ambient Temperature
20 °C|68 °F
Average Power, Ambient Temperature
40 °C|104 °F
Average Power, Inner Conductor Temperature
100 °C|212 °F
Return Loss/VSWR
Frequency Band
VSWR
700
894 MHz
1.13
806
960 MHz
1.13
1700
2200 MHz
1.13
AL4RPV
-
50R
page 2 of 4
April 12, 2019
©2019CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks,
respectively, of CommScope.All specifications are subject to change without notice. See www.commscope.com for the