© by SEMIKRON / 2017-04-20 / Technical Explanation / TechEx
®
Board SEMIX5MLI SKYPER 12 Page 1/10
1.
Introduction ............................................................................................................................... 1
2.
Application hints ......................................................................................................................... 2
3.
How to start............................................................................................................................... 3
3.1.1
20P primary side pinning.................................................................................................. 4
4.
Setting parameters ..................................................................................................................... 5
4.1
Active clamping..................................................................................................................... 6
4.2
Circuit diagram ..................................................................................................................... 7
Please consider the technical explanation of SKYPER 12 R L5069901 as all electrical functions
are described in there.
1. Introduction
The Board SEMIX5 MLI SKYPER 12 R is an adapter board which can be used for driving the MLI module
SEMIX5. The board can be directly plugged on the module.
Figure 1: Board SEMIX5 MLI SKYPER 12 R - 45135001
Fits to 600V, 1200V & 1700V modules
Drives MLI IGBT modules
I
outave
=50mA @85°C
Safe short circuit handling with SoftOff and active clamping
Important:
Please make sure to consider the three level error management application note when switching
MLI modules.
Technical Explanation
TechEx
®
Board
SEMIX5MLI SKYPER 12
Revision: 02
Issue date: 2017-04-20
Prepared by: J.Krapp
Approved by: Name
Keyword: IGBT Driver
© by SEMIKRON / 2017-04-20 / Technical Explanation / TechEx
®
Board SEMIX5MLI SKYPER 12 Page 2/10
2. Application hints
Gate resistors
The gate resistors can be assembled via SMD process. Gate resistors values should be chosen as low as
possible to have low switching losses. But over voltages over the full temperature range during standard
switch off and during short circuit switch off are the limiting factor and must be checked.
Active Clamping/ SoftOff
The active clamping has to be set according to the required DC link voltage and has to be proven during
short circuit conditions.
Figure 2: Dimensions
63,5mm
129,5mm