Technical Data Sheet
LMR Master
Land Mobile Radio Modulation and Signal Analyzer,
Vector Network Analyzer, and Spectrum Analyzer
S412E
9 kHz to 1.6 GHz Spectrum Analyzer
500 kHz to 1.6 GHz Vector Network Analyzer
S412E Specifications
2 of 38 PN: 11410-00486 Rev. AJ S412E TDS
Introduction
The S412E is Anritsu’s second generation solution for installing and maintaining public safety systems. Built on Anritsu’s
ninth generation handheld platform, the S412E combines a high performance receiver/spectrum analyzer with the world’s
most advanced handheld vector network analyzer plus a powerful vector signal generator with internally adjustable power
from 0 dBm to –130 dBm.
Land Mobile Radio Signal Analyzer Highlights
Spectrum Analyzer Highlights
VNA Analyzer Highlights
Signal Generator Highlights
Capabilities and Functional Highlights
Analyzes Narrowband FM analog systems
Analyzes P25 (TIA-102.CAAA-C), P25 Phase 2 (TIA-102.CCAA),
DMR (MOTOTRBO™)
a
, NXDN™, dPMR, ITC-R PTC, and TETRA
digital systems
100 kHz to 1.6 GHz frequency coverage (Optional extension
to 6 GHz)
Internal signal generator: 0.1 dB resolution, 0 dBm to
–130 dBm (spec to –120 dBm)
a. Supports those features compliant with the ETSI DMR standard.
2.0 dB signal generator accuracy (typical)
P25/P25p2, NXDN, and ETSI DMR BER test patterns
including 1011, 1031, and V.52/O.153
Duplex test: Simultaneous analysis and generation of
analog or digital LMR signals
Independent control of both receive/transmit frequencies
and test patterns
TETRA Base Station Receiver Sensitivity Measurements
Measurements: Occupied Bandwidth, Channel Power,
ACPR, C/I, Coverage Mapping
Interference Analyzer: Spectrogram, Signal Strength, RSSI,
Mapping
9 kHz to 1.6 GHz frequency coverage (Optional extension to
6GHz)
Dynamic Range: > 95 dB in 10 Hz RBW
DANL: –152 dBm in 10 Hz RBW
Phase Noise: –100 dBc/Hz max @ 10 kHz offset at 1 GHz
Frequency Accuracy: 120 ppb standard (25 °C ± 25 °C);
< 50 ppb after 3 minutes with GPS lock
1-path, 2-port Vector Network Analyzer (VNA) w/ quad trace
display
�� 500 kHz to 1.6 GHz frequency coverage (Optional extension
to 6 GHz)
Intuitive Graphical User Interface (GUI) with convenient
touchscreen
VNA-quality error correction for directivity and source
match
Outstanding calibration stability, up to 16 hours
Arbitrary data points up to 4001
IF Bandwidth selections of 10 Hz to 100 kHz
100 dB transmission dynamic range
850 s/data point sweep speed
500 kHz to 1.6 GHz CW/FM/AM Modulation
FM, 100 Hz to 10 kHz rate, adjustable deviation
AM, 100 Hz to 10 kHz rate, adjustable depth
0.1 dB resolution, 0 dBm to –130 dBm
CW, FM with CTCSS/DCS/DTMF, FM with CTCSS/DCS/DTMF +
Tone Modulation, FM + Tone Modulation
Analog FM and digital LMR analyzer
High accuracy internal power meter
On-screen LMR Coverage Mapping (Outdoor and Indoor)
GPS tagging of saved traces
USB data transfer
Complies with MIL-PRF-28800F Class 2 and MIL-STD-810G
Certified for use in Explosive Atmosphere per
MIL-PRF-28800F 8.4 inch daylight-viewable TFT LCD color
resistive touchscreen – allows use while wearing gloves
Touchscreen keyboard
USB and Ethernet data transfer
Web Remote Control
Master Software Tools™
3 hour battery operation time
LMR Master™ S412E featuring 8.4 inch Daylight Viewable Touchscreen
Compact Size: 273 mm x 199 mm x 91 mm, (10.7 in x 7.8 in x 3.6 in),
Lightweight: 3.6 kg, (7.9 lb)